r/askaplumberUK • • May 01 '26

Do we need to replace our oil tank?

Thumbnail
gallery
0 Upvotes

A few years ago we bought our house which is in a tiny village where there’s no gas lines.

Our oil tank looks very dated and we’ve finally removed the shed that was next to it to get a proper look at it.

There’s no cracks etc, it appears to be ok but it does look very old.

Based on the attached images, does it need replacing now or can we hold off for a few years? We’ve no idea when it was installed.


r/askaplumberUK • • Mar 13 '26

Plumber installed shower with this finish — acceptable for a £200 install

Thumbnail
gallery
5 Upvotes

I recently paid a plumber £200 labour to install a new Bristan Buzz bar mixer shower, and I’m trying to understand whether the finish I’ve ended up with is considered acceptable.

Before the job I actually wrote in the advert:

“The existing copper pipe attachments will likely need minor adjustments to ensure the new Bristan attachments fit properly.”

However, after installation the shower has been connected to threaded outlets coming out of the wall, and the result looks like this:

•	the brass threaded fittings are visible

•	the tile holes around the pipes are exposed

•	the decorative shrouds supplied with the shower can’t be used

•	the mixer sits about 10–15 mm away from the wall

From the Bristan instructions it looks like the shower is designed to mount onto ~21 mm copper pipe tails, with the shrouds sliding over and sitting flush against the wall.

My questions are:

1.	Is this considered an acceptable finish for a bar shower installation?

2.	Could the plumber reasonably have adjusted the pipework or connectors so the shrouds sit flush without opening the wall?

3.	Would something like shorter connectors or eccentric shower fittings with deeper covers normally be used here to hide the pipework?

I’m not expecting miracles if the existing plumbing made things difficult, but given I specifically flagged that minor pipe adjustments might be needed, I was expecting a neater finished look.

Photos attached for context. Would appreciate any opinions from plumbers or people familiar with shower installs.


r/askaplumberUK • • Oct 17 '26

Is £1,202.50 a fair quote for boiler repairs, 3 radiators and an outside tap? (UK, North East).

1 Upvotes

Just bought our first place and the boiler hadn't been serviced in about 10 years. A plumber came to service it and found it needs some work. While he's here, we also want a few other jobs done, so I'd love a sanity check on the price.

Drain the system, lift the floorboards in both bedrooms, pipework for both radiators, supply materials, install the two column radiators, pressurise and leak test: £417.50
Boiler annual service: £70
Supply air vent boiler part, gasket and temperature sensor: £84.50
Replace all parts, leak test, and CO/CO2 check with an analyser: £120
Outdoor mixer tap supplied: £117.50
Hose and shower handle spray: £22
Wall plate: £12
Materials for outdoor tap pipework: £24
Install outside tap: £130

Quote total: £997.50

On top of this, I've asked for a third radiator to be added (the second one in the big bay), which is £205 extra.

That brings the total to £1,202.50.

They'll have two labourers on the job.

My questions:

Does this seem fair for the UK, or are any line items out of whack?

Is £205 reasonable for the extra radiator when the pipework is already being done?

Is £117.50 for the outdoor mixer tap itself about right, or should I source it myself?

Should I be asking for anything else?


r/askaplumberUK • • 12d ago

Waste Pipe

Thumbnail
gallery
0 Upvotes

Hi Advice needed from all you experienced plumbers🙏. We recently had our Bathroom refurbished and where left with this debacle. Unsurprisingly after only three days of use, the angled connector blew off during a flush. What should I demand the plumber does or carry's out to rectify this?


r/askaplumberUK • • Nov 25 '25

Fair price?

Post image
0 Upvotes

Hello, I recently hit a pipe in my wall (cold water in). I did all the work to take back the wall and expose the pipe, and had a plumber come out to do the repair. The guys were really nice, and had the job done in 9 minutes on the dot and used a single repair band (see picture). I have since been invoiced £150 + vat (£180 total).

I don’t want to be a dick about it, but this seems really high to me. Would you guys quote similar?

Thanks!


r/askaplumberUK • • May 21 '26

Is this manifold insulation safe?

Thumbnail
gallery
3 Upvotes

Hi…

The pipes under the tiles are not insulated when fitted. This under stairs area is becoming sauna when the heating is on.

I insulated the pipes as much as I could to prevent heating this space. I don’t know how to insulate the horizontal bars under the actuators and the flow red stuff.

This will not solve the problem of the tiles here becoming hot so I am thinking of laying a plywood board and leave some gap near the walls to prevent stressing the tiles and pushing them to crack.

But for the pipes… is this safe for the manifold to run like this? Any other tips are most welcome.


r/askaplumberUK • • Mar 26 '26

What’s a small mistake homeowners make that always turns into a bigger plumbing issue later?

0 Upvotes

I’ve had a couple of minor things at home that didn’t seem urgent at the time, but ended up becoming bigger problems later on. Made me realise I probably don’t know what’s fine to leave vs what needs fixing straight away. From your experience, is there something people commonly ignore that always comes back to bite them?


r/askaplumberUK • • Feb 22 '26

Boiler makes this noise.

0 Upvotes

I have the option of this sound echoing down the street and making the dogs bark or sitting in a cold house. Has anyone suggestions on what it could be ?


r/askaplumberUK • • Oct 27 '25

My house is boiling help

Thumbnail
gallery
0 Upvotes

So my Honeywell thermostat is connected wirelessly to this other thermostat looking device that’s neer my boiler. When I press automatic I hear a little thing then it turns on but no heating to the radiator. Coz it was so fucking cold I jsut pressed manual and then turned it off. After that boom all the radiators became boiling and the house was warm. Now obviously that’s good but then it gets too hot. What do I do then. Is there no middle ground. I don’t want to turn it off for it to then be freezing then after that a whole ass sauna. Help me


r/askaplumberUK • • May 19 '26

Is this pipe still in use

Post image
0 Upvotes

Recently moved into a 1950s house, the chimney breast was bricked over with another separate brick wall. After taking all the bricks off I found that the fireplace used to have a back boiler so there’s old redundant pipes that I want to cut..they’re not capped so I don’t think there’s any water left in them or anything..there’s also this pipework. The radiator pipes come down the inside of the chimney and exit into the kitchen feeding into the radiator so I know the ones on the left are fine and won’t be touching them.my question is can I remove the one with the drain on it or is it connected to the radiator system..I haven’t tried opening it yet to see if it’s dry or being used but it just seems like a really strange place to add in a drain at the end of the system..any thoughts would be greatly appreciated


r/askaplumberUK • • Nov 03 '25

New Worcester Bosch Boiler Warranty

0 Upvotes

New - 10 months since install - Greenstar 4000 30kW Combination Boiler

At the time of install I asked about warranty - install engineer said 'we keep the warranty'

Sounded dodgy to me

No heating or hot water yesterday

Error code 0.3Bar - low pressure

Call plumbers who installed it and asked if labour and parts covered if they come out to fix

Lady didnt know answer - 'asked the boss'

Only parts covered or some wishy washy answer

Call Worcester Bosch customer support-

They say boiler warranty not registered

I register the boiler with serial number

I ask if we can ask the installers to fix it and then charge WB the parts and labour

WB support say no - the original installers can diagnose it - but only way to have parts and labour covered is to have a WB engineer fix it

He then asks for error code

I say above - he says oh you can fix that yourself -we wont fix that

There should be a blue lever - underneath - apparently his boiler needs 'topping up' every couple of months

Had an ideal boiler before for 15 years - never topped it up once

There is no blue lever underneath - guessing that must be an older model

We did try and move some black lever on a coiled pipe over the weekend. Didnt seem to want to move clockwise or anti clockwise

Even so - what is this nonsense. DIY fix it yourself with some guy in a call center?

At the end I said - will you pay for parts if installers change them - then he says yes

Anyone know what the actual process is supposed to be?

Thanks in advance!


r/askaplumberUK • • Mar 16 '26

AM I OVERREACTING - DEAD LEGS?

0 Upvotes

I (F39) and my partner M32 moved into emergency accomodation in Feb 2024 after a no fault section 21.

The house we moved into is a council property and it was supposed to be our fresh start however, ever since we moved in me and my partner have been getting poorly - really poorly...through power of elimination I narrowed it down to the water supply into our home. NOT UU (United utilities) and I've had 17 Positive coliform tests.

My partner has a look in the loft and there are 2x20ft dead legs still attached to the hot water system from the old tank in attic and we believe that's whats been making us sick.

HOWEVER

It all sounds pretty straight forward BUT .....

The housing landlords don't seem to be as worried and concerned as I am.

  1. The told us they would cap it off and leave the 2 dead legs inside the wall.

  2. They told us that they didn't have any professional testing and would have to send it away - which they have.

  3. The Drs surgery are treating me like a psycho - because it's been such low level Infections as they are hard to identify.

So plumbers of the UK.

Am I OVERREACTING? Should the landlord be doing more? Are the pipes as dangerous as I think they are?

Any experiences or advice would be appreciated?

I feel like I'm going nuts!!

EDITS THANKS FOR THE REPLY ALL.

FURTHER CONTEXT-

I have done 17 coliform tests. We have 7 taps in the property..

2 = kitchen 4= Bathroom 1= outside.

All of them were tested a few months apart - every single one of them were positive for coliform.

The 2 dead legs stretch from the first floor back wall, up into the loft to where the old tank used to be. The tank has been removed but there's 2 lengths of 22mm pipe capped off in the loft but still attached to the supply in my back room.

I truly believe that we have legionella and Pseudenomas... I'm just shocked that the landlords, as a housing group haven't jumped into action.

Since writing the original message - We've found out next doors is the same and she has also been poorly... So it looks like the whole street could be at risk.

THANKS FOR ALL OF THE RESPONSES - I FEEL A LWTTER RO Environmental Health coming on!


r/askaplumberUK • • Jan 24 '25

New bath (with tap shower), sink, toilet, tiled wall and floors - £9000. Is this a total rip off?

0 Upvotes

Morning chaps. Recently me and the misses went to wicks and talked to them about new bathrooms.

They gave us a ball park quote of £9000 which tbh felt off at the time.

I've gone and done a few quick searches online and have found the following average prices for new equipment and its installation

bath with tap shower (£1000)

Toilet (£500)

sink (£500)

Tile floor and walls (£1000)

Total - £3000

What am i missing with this? On websites as soon as you type in "new bathroom" you get things like "the average price is £7500, yet when i price the jobes up individually i get £3000

This is a huge discrepency. Are wicks just taking the piss?

(nb its a small bathroom, probably width and length of a bath tub, so around 2m2, maybe a smidge bigger. 7ft by 7ft or what have you)


r/askaplumberUK • • Nov 03 '25

Adding 3 bidets to washrooms in home, quote of 450 + VAT.

Thumbnail
gallery
0 Upvotes

Hi all, I am adding 3 bidets to the bathrooms in my home in the EN11 region (north of the m25) and I have been quoted 450 + vat. Could you please let me know if that is a reasonable quote. The bidet I am looking to install is from B&Q (https://www.diy.com/departments/nes-home-douche-shower-spray-kit-with-holder-hose-chrome/7426764415080_BQ.prd) Thanks!


r/askaplumberUK • • Nov 18 '25

Can I install a thermostatic valve on this?

Post image
0 Upvotes

r/askaplumberUK • • Oct 21 '26

Main combi eco 30 leak

0 Upvotes

I have a main combi eco 30 boiler.

Water has been leaking on the side.

I have opened it up, dried out this section where water had collected then turned it on.

The leak seems to be somewhere at the back.

What do you think the cause of the leak is and how can it be repaired?


r/askaplumberUK • • Oct 20 '26

Replacement Shower Cartridge

Post image
0 Upvotes

Hi

I think I need to replace the shower cartridge - regardless of which way or how much I twist the end, the temperature of the water doesn’t change.

However, I’m struggling to identify a cartridge that will work, they all seem to look differently sized/made! I’m tempted to get a plumber out to have a look and source me a part, but for such a simple swap I’d like to try and sort myself

Any ideas? Tips for next steps?

Thanks


r/askaplumberUK • • Feb 04 '26

Can an electric shower be installed here without hiding cables in the wall?

Post image
2 Upvotes

We had our bathroom done recently and we're planning to get a shower that has the pump in the loft (power shower?) so the tiling has been done. However we were since advised not to go with the power shower (not ideal, I know!) as our water tank is small and would empty very quickly so now we are looking at alternatives.

Would it be possible to install an electric shower and hide the cables in a chrome pipe, similar to a power shower? Do electric showers have the option of the cables coming from the top or are they all from the back? Any other options we could look at?


r/askaplumberUK • • Jan 08 '26

Legionella risk with a combi boiler with pre-heat enabled, set to 45C?

1 Upvotes

I know there's a Legionella risk for hot water below 50C if you've got a water tank, but as far as I know, that's not a risk with combi boilers since the water isn't stored in a tank.

I could do with some advice when it comes to the pre-heat mode on my boiler though (Glow Worm calls it "warm start"), since I don't really understand how that feature actually works.

Is there some sort of tiny water tank inside the boiler which is kept at a warm temp, or is it somehow doing that without water storage? And would that then bring in a Legionella risk by keeping it set to 45C?

Thanks!


r/askaplumberUK • • Oct 15 '25

I have a 15mm gas line running through the kitchen, will an engineer attach a t to supply a gas connection to the garden for bbq or does it have to be 22mm?

1 Upvotes

r/askaplumberUK • • Apr 05 '26

Is this exit pipe the reason my toilet keeps clogging?

Post image
1 Upvotes

My toilet keeps clogging and I think it’s due to this pipe getting backed up. I’ve noticed the pipes on the neighbours are a lot longer and at a steeper angle before connecting to the downflow pipe. Is this pipe too shallow and should it be replumbed? Thanks for all advice!


r/askaplumberUK • • Jul 17 '26

Leaky Shower Even Though Sealant Intact

1 Upvotes

My shower is leaking. It seems like the water is going into the silver part on one side of the glass, then coming out the other side. The sealant seems intact so I guess the problem is happening above it. A second leak starts to appear near the end of the video, also coming out of the silver part. What could you do to stop this happening?


r/askaplumberUK • • 21d ago

what is this and should it just be hanging out in the open?

1 Upvotes

Mum recently had a new oil boiler put in after the previous one was condemned. In the process the new boiler was moved to the garage.

I've visited for the first time since the work was done, and I spotted this contraption next to the kitchen door. The wall it's attached to is the back wall of the garage. The label says "Fuel stop".

Should it just be hanging out in the open here? It looks kind of fragile if someone trips over it or drops a big plant pot on it or something.


r/askaplumberUK • • Aug 29 '26

​Plumber repaired 32mm lead pipe with kinked 25mm MDPE. Now my top-floor flat is experiencing low water pressure. Is he at fault?

Thumbnail
gallery
16 Upvotes

Problem solved! I’d like to thank everyone who contributed. It turned out to be, as most of you suggested, clogged filters. Everything is working fine now. It was such a simple solution that I can’t get my head around why the plumber who fixed the leak didn’t think of it.

A plumber was called to fix a leaking lead communication pipe. The pipe supplies three flats in a three-storey block, including mine on the top floor.

The external diameter of the lead pipe is 32mm. To fix the leak, the plumber used two connectors and a short section of 25mm MDPE pipe. The problem is that the water pressure and flow rate have decreased significantly, to the point that my electric shower has stopped working properly. The plumber doesn't seem to think he did anything wrong and is trying to convince me that my water pressure is fine since the neighbours in the flats below aren't experiencing a pressure drop. Am I right in thinking that using a 25mm pipe in this case was a bad choice and caused the pressure problem? He also forced the plastic pipe, creating two kinks which, in my opinion, only add to the problem.


r/askaplumberUK • • 23d ago

Quote for reroute of pipe

Post image
0 Upvotes

Hi, I wondered what your views are on this quote I received for rerouting my hot water. The pipe under my kitchen floor has been capped off following a leak. The vinyl and screed has already been removed.

The quote is for a new trench about 2.5 metres long and a new bit of pipe to go direct towards the sink. The insurance is already paying for the floor to be made good afterwards.

It seems rather excessive, and surely plumber and labour are the same thing charged twice, no?

Edit: I have pasted the quote into notepad so that I don't capture personal information in the photo. It was just quicker this way when working across devices. The quote is from the sub-contractor of the insurers sub-contractor who will be doing the restoration work following the underfloor leak.