r/firealarms • u/Camfurt • Mar 01 '25
Fail Sealed away like a curse
Inspection at a campus and found this poor pull station sealed away. Made me laugh I’m sure someone else will find this funny as well
r/firealarms • u/Camfurt • Mar 01 '25
Inspection at a campus and found this poor pull station sealed away. Made me laugh I’m sure someone else will find this funny as well
r/firealarms
•
u/theqbanbro
•
Feb 12 '25
Hey everyone,
As a former fire alarm field tech, I always wished there was a single place to quickly access fire alarm panel manuals while out on the job. I know the struggle of digging through outdated PDFs, searching across multiple manufacturer sites, or hoping you saved the right manual on your phone.
I created facpmanuals.com, which is a free and growing database of fire alarm panel manuals. My goal is to make this resource as user-friendly as possible and easily accessible on both mobile and desktop.
I’m a solo developer, combining my two passions—fire alarm systems and web development—to build something that I hope will help other techs in the field. The site is still growing, and I’m adding new manuals every day. If you have suggestions or specific manuals you’d like to see added, let me know!
This project is 100% free, and I just want it to be a useful tool for anyone who needs quick access to manuals without jumping through hoops. If you think this would help you or someone you know, check it out and let me know what you think!
Would love to hear any feedback from the community. Stay safe out there!
r/firealarms • u/I_got_erased • Jun 13 '24
r/firealarms • u/Broad_War • Mar 06 '26
Found on crappy fire alarm on facebook
r/firealarms • u/Electronic-Concept98 • Feb 23 '24
Why?????. And the Inspector passed this!!!!!
r/firealarms • u/MandoO6d6r • Feb 05 '26
Seen this during an inspection. Fire department won’t make them take it down.
r/firealarms
•
u/CannedSphincter
•
May 21 '26
r/firealarms • u/black_chris_hansen • Aug 28 '25
It means your fire alarm blinker fluid needs to be changed
Full drainage video: https://i.imgur.com/Appgbl4.mp4
r/firealarms • u/Temporary_Piglet_624 • Feb 24 '25
I made it boys! Im NICET LVL 4 now.
r/firealarms • u/toke1 • Mar 06 '25
Short on a speaker circuit for a 6 story hotel.
r/firealarms • u/justacr33p • Nov 10 '24
My boy got a set of Snap Circuits for Christmas last year. We have had a ball with them. Last night I decided to make a fire alarm with him just for giggles. Needless to say everyone in the house had to have a go at pulling a pull station!!
I know it could be optimized but I done it this way specifically to show the difference in the data and the NAC.
r/firealarms • u/ProfessionalInjury29 • Jul 18 '25
r/firealarms • u/coolinui • Dec 20 '24
40 year old 14 story hotel. 2nd system installed 25 years ago. Many trunk slammer later.
r/firealarms • u/ChrisR122 • Oct 09 '25
Got called out last night to an emergency service call, system wouldn’t reset, fire department still on scene. No lights in the entire place, so I’m walking around with a headlamp trying to figure out what’s going on.
Turns out unlicensed contractors were doing non-permitted work in the middle of the night to avoid getting caught. The owners wanted to convert the space into a nightclub, and apparently thought they could just “take the ceiling down and throw up some sheetrock.”
So they ripped down both the drop ceiling and the original 100-year-old tin ceiling.. by hand. Took every fire alarm cable down with it. Multiple wires cut, shorts everywhere, the whole system’s toast. Total replacement needed. And now, of course, everyone’s claiming they “can’t pay for it.”
The part that really got me? They were demoing an ancient ceiling, in total darkness, with zero PPE. I told them, “You have no idea what was in that ceiling. Asbestos, lead paint, rat poison, who knows.” And one lady was walking around with a surgical mask like it was an N95.
Wish I had better pictures, but the only light in the place was from my headlamp.
So… what do you guys think? Gross negligence, or just another customer trying to save a buck?
r/firealarms • u/matthebastage • Nov 20 '24
Two 110AH batteries, that have to be replaced. I HATE whoever decided to put this here