r/ukelectricians • • Sep 29 '24

Why are electricians so against DIY'ers?

0 Upvotes

Backround: I rewired my house and - eventually - found an electrician willing to certify it with some distant supervision. I purchased the BS 7671 On-Site Guide and found it sufficient for my house. In general, it was pretty simple. One has to choose sufficient conductor sizes given the circuit, and derate it given the number of circuits it travels alongside for the prescribed distance, and method of installation (clipped, chased, insulated, etc). Chase depths, joist holes, minimum bend radius, earth bonding conductor size, cavity wall intersection, etc. For domestic instalations it's all in there.

But whenever I watch a YouTube video about sparkies demonstrating a termination or whatever, they all seem to have an air of superiority or contempt when the subject of non-electricians come up. And speaking to sparkies in person, they all seem to have an elitist attitude about their jobs.

I work in tech and this kind of attitude is heavily frowned upon within my field. Is this them covering their own arses with regard to providing online "advise"? Or maybe then assuming all members of the general public are absolute simpletons?

EDIT - just to be clear, the sparkie visited multiple times throughout the works. I showed them how I was routing the cables about below the floorboards etc. So they did get to see everything.


r/ukelectricians • • Mar 15 '26

Kitchen switch grid removal advice

Post image
1 Upvotes

Hi all,

I'm doing some rewiring in my kitchen and could use a bit of advice before I start removing anything.

I currently have a "switch grid" on the wall (see attached photo) where each switch controls a different socket around the kitchen. As part of a small refit I'm planning to remove most of those sockets, and the ones I keep I no longer want controlled by this panel. A number of the sockets are on the opposite side of the kitchen to the switch grid.

My question is: How are these likely wired in terms of their connection to the ring and what's the best practice for dealing with the wiring behind these switches once the sockets are removed?

Ideally I’d like to:

  • Remove the redundant sockets

  • Remove the switch grid

  • Leave the dishwasher, washing machine and tumble dryer sockets active but not controlled by this panel

I have very little technical experience in this kind of thing so keeping it in layman's terms would be highly appreciated!

Thanks in advance.

Edit: Just realised I should have posted this in r/DIYUK so, I guess feel free to shoot me down for attempting something I probably shouldn't.

Edit 2: To avoid too many more gatekeepers and angry professionals: I'm almost certainly going to get an electrician to do this work for me. I am interested in learning new things and building understanding of how systems work. My goal is firstly to be able to actually communicate what I want doing while having at least some understanding of what the undertaking involves. I'm also hoping to be able to do some preparation work so that a highly skilled man of lightening doesn't spend too much of his precious, and expensive, time breaking through plaster.


r/ukelectricians • • Mar 10 '24

This sub is a mess and devalues our trade.

6 Upvotes

DIYers and other people with no knowledge asking questions to avoid paying for our services. 🤷


r/ukelectricians • • Mar 17 '25

To everyone who answers DIYer’s posts:

0 Upvotes

What are you going to do when someone follows your advice and accidentally kills or severely injures themselves? Maybe they'll switch off the light at the switch when changing a fitting and not realise that the loop is still live, maybe they'll swap a socket and not realise that the switch on the front doesn't make the cables feeding it dead. They might not be lucky enough to have RCD protection, and instead have an old rewireable fuse, ready to dump a whole load of amps through them without tripping.

Emboldening people to have a go at electrical work by giving them advice is incredibly stupid and dangerous. There might be careful and conscientious DIYers out there, but by giving them advice you are potentially making yourself liable. And not to mentioning degrading your own trade. Stop trying to help people do work they're not qualified to do.

Edit: and one thing I'd be curious to know, to those replying and voting on this post: are you a qualified electrician (gold card holder or equivlent) or are you a DIYer? The question that no-one wants to answer it seems. Which makes me wonder how many of those leaping to the defence of DIY aren't sparks at all.


r/ukelectricians • • Apr 23 '23

DIY Consumer Unit Change

1 Upvotes

I know this will get downvoted to hell but I will be doing a consumer unit change in my house soon as i can't find any law which says I can't.

I'm not an electrician but I have extensive experience in the field of electronics and all the theoretical and practical knowledge on how to do it.

I don't like all the stigma around DIY electrics. If you follow the proper regs and do the work to a high standard you usually get a better result than a 'qualified' 18 year old sparky out of college.


r/ukelectricians • • Jun 19 '25

Such clean and finished work done.

Post image
0 Upvotes

r/ukelectricians • • Oct 01 '25

Hello, could anyone advise me on the correct way to wire up this outside light sensor?

Post image
0 Upvotes

The colours don't seem to match any chart I can find :(


r/ukelectricians • • Feb 07 '26

Looking for safety advice - powered reclining chair - UK

Thumbnail
gallery
0 Upvotes

I bought a reclining chair from Amazon, it was a good deal and seems to work, but based on the manual clearly made in China.

I was just wondering if there was any obvious issue with this plug and adapter in case there is any change I could make to make it safe if anything looks out of place?


r/ukelectricians • • Jan 07 '25

Silly regulations and why

2 Upvotes

Anyone got any regulations they think are stupid? I've got a couple...

Why in Christ's name do we have to sleeve/label conductors? If you can't glance at a switch and identify what is going on, you shouldn't be looking at it!

Bathroom regs...May have been suitable in the 50's when you just moved a 3 bar heater into any room you where in. Today, its just stupid. Socket in a bathroom's fine, as long as 3m away. Or if you put inside a cabinet... Perfect sense. Or perhaps literally outside the door within reach of the tub? Yup no worries there.

And another bug of mine...EICRs. There has got to be some better formal training for them. How isn't there more regulations surrounding them?! But instead we have to install SPDs at every domestic property. What a waste of customers money.


r/ukelectricians • • Oct 07 '26

I regularly break regulations.

2 Upvotes

Redditors love to point out things that don’t meet code, but how wrong is it to break regulation because of circumstances.

Examples:
An existing socket being moved and then plastered over.
Wall light being removed.

Regulations:
Zones, maintenance free enclosures

In these examples it may be difficult to find an enclosure that would span and cover all the cable that might be expose inside a backbox or an enclosure that will snugly fit inside a shallow connection point for a wall light.

Capping off either of these point could also leave buried cable in a wall with nothing to identify the Zone.

How do electricians practically tackle issues like this, where the most straight forward and sometimes only practical solution is to break regulation.


r/ukelectricians • • May 29 '26

Questionable Consumer Unit Install

Post image
0 Upvotes

Hi all

I have an ongoing extension and our builder has his contracted electrician on site. I understand a little about how the set up is but I am seriously questioning what is happening here.

AI thinks it's non standard, which I'd agree with.

Is anyone able to explain what I need to be doing with this?

I am not sure if this is the best sub to post it in so if it should be elsewhere then let me know.


r/ukelectricians • • Dec 29 '25

Cost for UK power networks to move the overhead supply

Thumbnail
gallery
0 Upvotes

Looking to purchase a property and planning to do a two storey extension to the side. It’s a fairly standard house, power supply is from 1940 and comes from an overhead line to the side wall. Property needs a full rewire and will also need to move the supply from the side wall to the front wall, along with upgrading from 60A to 100A main fuse.

Property is under UK power networks, tried using their online tool to estimate the cost to move the supply to the front wall/corner and it suggests that this will cost ‘From £10k upwards’.

Am I going crazy or is this not reasonable? What experience do other people have?


r/ukelectricians • • Sep 28 '25

Help with 3 way circuit.

Thumbnail
gallery
0 Upvotes

Hi, very new to the forum.

I live in a two year old apartment and have fairly domestic knowledge of electric connections.

I have a intermediate switch in our kitchen. It has three switches from three parts of the kitchen for turning the lights on/off.

I would like add another small light in the kitchen to this existing circuit.

I was under the assumption that I could directly add one to one of the switch boards. But the more I read / see videos, more I am confused.

Below is a picture of the switch to which I would like to add. It looks like an intermediate switch.

  1. Is it possible to directly add another line to this circuit?

  2. If so, where should I connect live and neutral?

Also: I have 5 LED light bulbs on this circuit and the light I'm planning to add is an 8W strip light. Please let me know if you need any other information.


r/ukelectricians • • Jan 16 '25

I got a cooker for free and it has no plug - can I safely attach one or do I need an electrician?

Post image
0 Upvotes

It has the Earth, Live and Neutral wires - but I was under the assumption the Earth is a twin cable? So attaching a plug wouldn’t be a simple process. Is there anyway I can safely add a plug to this so the cooker works - or is it best to call an electrician?

Thank you! I have done a bit of reading via Google but I’d rather get advice directly from here so I’m not putting anyone in danger.


r/ukelectricians • • Dec 12 '25

Running electricity to a detached driveway

Post image
0 Upvotes

I have a tricky setup. My driveway (where I want to install a socket connection and an EV charger) is marked in green. My house — where the supply would come from — is where the photo is taken from.

Between the house and the garage, there’s:

  • A public footpath running directly in front of the house

  • My neighbour’s driveway, marked in red (although I could route around it, but that would mean going on the street)

So I’m trying to figure out what’s realistically possible and what permissions I might need (neighbour, council). Any advice from experts would be great.


r/ukelectricians • • Dec 30 '25

Against regs or is okay? Securing cables inside joist notch

Post image
1 Upvotes

Hi all. I have my subfloor lifted and is being replaced but these cables keep coming out the notch. Atm its not safe for me to put the osb downas the theres a big risk the cables will be crushed and exposed and my house will explode (sarcasm)

Is there anything in regs against this? Its mainly to stop cables moving and they can sit loosely and be easily moved and doesnt get crushed by the osb.

From what i saw and read from BS 7671 – IET as long as its non obstructive, these are okay to use but just wanted a second opinion, thanks!


r/ukelectricians • • Oct 13 '26

Is the industry ruined?

1 Upvotes

I went self employed as a subby in June this year after being on the books for 5 years, started on a job in the midlands for a few months but now it’s coming to an end, and I’m struggling to find more work. I feel like I’ve made a big mistake and should’ve stayed on the books. Am I doing something wrong or is the industry just rubbish at the moment? Is anyone else struggling to find work?


r/ukelectricians • • Nov 01 '25

Why won’t this black switch in my fuse box stay on?

Post image
0 Upvotes

The Power in my house just went out and I checked the fusebox and this black switch was off,I switched it back on and power came back to my house but it switched itself off again after a few minutes. Now when I switch it back on no power returns to my house despite the mains switch being on. Could anyone let me know what’s going on and what I can do to bring back power? Oh and I’ve also just paid the electric bill so that’s not it. Kind regards.


r/ukelectricians • • Feb 28 '26

Can I use this plug? Why is it like this?

Post image
1 Upvotes

Sorry if this isn't the place to ask, but I just moved in to a guardianship property, and some of the plugs in my place are like this. Are they safe to use as a standard plug? What is different about these?


r/ukelectricians • • Nov 01 '25

EV Charger Install (struggling to find an installer, is there anything wrong with my requirements)

Thumbnail
gallery
0 Upvotes

So I'm looking for someone to install an EV charger and I'm struggling to get anyone to actually give me a quote.

Specific requests / requirements :

  • I would prefer to use the space way on my consumer unit if possible (id very much like to avoid a separate one for the EV charger, mainly for neatness) the unit is all RCBOs it's a BG so I think CUCRC40DPA works type a / double pole (iv attached a photo of my consumer unit for reference)

  • I would prefer to run the cable (6mm or 10mm singles whatever is needed) in conduit rather than using SWA or EV untra clipped (my network switch is in the other direction so I would run separate Ethernet to the location before the install if needed)

They only annoying point is that someone in the past moved the consumer unit into a cupboard in the kitchen about 1m away from it's original location.

Meter box already has had an isolator fitted and larger tails fitted between the isolator and the meter.

I have contacted 4 electricians locally and :

  • 1 said I would come 2 Fridays ago, last Friday I chased them they said "oh was have you in for next Fri/ 31st" yesterday.... Still no show (I did not give any of the above requirements just sent pictures of the CU and meter box)

  • another came round, I ran through the location of the charger and what I would like, he said he can use the current consumer unit fine, but wants to run SWA. I was happy enough with that , he said give him a week to get a quote back...... Nothing.

  • contacted 2 others, they said they would come back to me with a date to get a quote.... Nothing (again I didn't ask for anything specific with these two, just my address and location on the house I want the charger and pictures of the CU and meter box)

Something I haven't asked any of them is that if they would install an Easee one charger (new in box) that I have inherited from a friend who had one spare. And (understanding there would be no warranty on the device) would like to use that to save it from e-waste.

So my questions are :

  • are my requests viable around using my main CU and running cable in conduit.

  • is there any trick to finding good reliable electricians ? (So far iv been using Google)

  • I'm assuming most are just looking for simple installs (mine even using SWA and a separate consumer unit is a fair run 8-9m from the meter box around the house)


r/ukelectricians • • Jan 31 '26

Joiner making a mark up on my work

3 Upvotes

Done a couple of wee electrical jobs for a joiner. I am to send him the final bill and its him that pays me not the customer and he clearly specifies this is how payment is to be made. He is never at the job and no joinery work is being done. He just sends me a number and a rough description of the job so I organise it with the customer.

I am now realising that he is making a mark up on my work for just giving me the job without being involved. There is no way he charges the customer what I charge him. Easy money for him. What would you do in this situation? It makes more sense to get paid direct from the customer? Is he due a referral fee?


r/ukelectricians • • Jan 12 '25

Ban of DIY electrical work

1 Upvotes

Hello all

Seeing a lot of mentions of banning diy electrical work on YouTube and the like. What are your thoughts as many don't seem to have much of an idea how it would practically work. What would be your proposal if you were government around this issue?

Do you think an extension of part p notifiable work would be best or a complete rework of the whole system?

Do you think diy electrical work should be banned, system changed around work certification or no changes at all?

Thanks all for your thoughts


r/ukelectricians • • Mar 25 '24

£3,648 Inc VAT. Does this quote seem reasonable to you? South East UK.

Post image
1 Upvotes

I had an EICR done on a property my wife and I inherited to rent it out. He said the following fixed were required (c1/c2). I asked him how many days work it would be and he said '3 days / 3 visits'.

I'm getting a second quote from an electrician I've used before, he said he can fix the issues but I'm not sure how he could update the original electrician's EICR report. Is it possible to do this?


r/ukelectricians • • Sep 24 '26

Is this safe?

Post image
1 Upvotes

Mate had his new combi boiler installed recently, is this pipework safe near his electrical board?


r/ukelectricians • • Oct 18 '25

Wire exposed ?

Thumbnail
gallery
0 Upvotes

Hi, I've just had my home rewired and the electrian seems to have left a wire exposed in a bedroom socket. I'm in the middle of insulating and plastering but should I stop and get this fixed first? I assume this is the grounding wire with no current but still.. Thanks for opinions, thoughts and advice