r/heatpumps • • Dec 07 '21

Learning/Info **Heat Pump Quote Comparison Survey**. This is a community resource to enter your received quotes to help others. The link brings you to the survey, and the results are linked in the comments. Please share far and wide.

Thumbnail
forms.gle
128 Upvotes

r/heatpumps • • Nov 26 '23

Serious mod announcement: With the growth of the sub, there has been more people from the trade migrating to this group. I've also noticed an increase in shaming, rude behavior, and victim blaming. I have zero tolerance for these behaviors as the first rule is kindness. Read text for my response.

364 Upvotes

This sub has a purpose to kindly help people with their heat pumps and provide a place to go to for interesting and fun happenings related to heat pumps. This is how I built the sub. To be for the betterment of all, and the advancement of the technology.

I have avoided banning people for a couple years now (unless absolutely needed), but the sub is now large enough to be more than just enthusiasts. Moving forward, and under Rule 1, I will start to immediately ban any shaming, rude behavior, and victim blaming.

Straight up, I don't get paid for this moderator position and I can't be asked to spend hours a day writing and correcting behaviors one by one with long text. I really don't mind that given the new personal policy that we could even lose half the sub from unsubscribing, because we need to work together and be kind and kindly helpful, and if only those who are left follow this, then that is a better place for those who remain.

Listen, I am a kind person in life. I try treat people fairly and giving them respect for being human and trying their best. I am also only kind to all to a point, and it stops when others are shamed, disrespected and blamed for doing their best. Life is hard enough as it is. If you are having a hard time in life don't take it out on others here. Find inner peace or emotional happiness first, then come back to the sub that way.

If moving forward you are banned and feel you want a second shot or would like to appeal, I will listen and consider.

Thank you everyone for reading, and thank you for considering my new personal policy.

Regards,

Geoff


r/heatpumps • • 9h ago

Heatpump Hotwater installation reviews please

Thumbnail
gallery
31 Upvotes

Live in Hamilton NZ and had this Haier unit installed, but I'm a disappointed with the position and pipe layout. If any of you have knowledge about this sort of thing, could you please post some feedback.


r/heatpumps • • 21m ago

Panasonic/Moveair or Mitsubishi - Hamilton Ontario

2 Upvotes

I'm replacing my 18 y/o oil furnace with a CC heatpump. The two best quotes that I've had are from the same installer and are either the Panasonic INTEROS (Moveair) 3 ton unit or the Mitsubishi Zuba. The price difference is about $3K, with the Panasonic also being an estimated $150/year less to run. It looks like warranty is the same for both.

I was going to go for the Mitsubishi, but given the specs and warranty, I'm not sure it's worth the extra 1-1/2 year payback.

I'd appreciate any thoughts/feedback if you've had experience with either/both of these.

Cheers!


r/heatpumps • • 4h ago

Bryant mini split

1 Upvotes

Hi! I’m a renter and landlord recently installed Bryant mini-splits (in Massachusetts). Ive noticed when I turn it on for hearing, my wall unit doesn‘t seem to “trigger” any air and nothing comes out. I’ve tried waiting upwards of 30 minutes, and it doesn’t seem to start blowing unless I turn up the temp up to like 71, at which point it starts blowing after a while. That doesnt really bother me, but I want to make sure it’s not a sign of a bigger issue.

Also, is it normal for it to constantly be blowing air (doesn’t seem to stop even when temp is reached)? I’ve had mitsubishi mini splits, which would periodically stop blowing air and the vanes would turn back upwards. These bryant ones seem to blow even when in the upwards position. I’m just worried it’s excessively using electricity

TIA for answers! I don’t know much about hvac 😅 Im mostly wondering if they’re all a little finicky or if I should ask for landlord to sent a tech to check it out


r/heatpumps • • 15h ago

Question/Advice Is this normal?

Thumbnail
gallery
6 Upvotes

Hi there. NZ here. Heat pump installed a few months ago. Noticed a hole in the wall poking out behind the side of the main unit and now I'm worried that our installer was a cowboy..

I want to let off a bug bomb in our roof, but I am worried about fumes pouring into our living room. Also worried about heat / moist air getting into the roof spaces through these gaps.

Pics of install attached.

The wood trim is the level of the second ceiling in the room behind the heatpump. Old house so there is a decorative lower ceiling that has been added to the bedrooms.

I think he may have mucked up and drilled the hole before checking which ceiling he was drilling into..

Pretty confident the condensate pump is tucked in this hole behind the unit.

Everything is routed up the conduit into the higher roof space. I can see a gap around this, too.

Is this normal?

I have tried contacting them about other things, but can't get hold of them.

I think the condensate pump runs for too long as I can hear sounds like someone sucking on a straw in an empty McDonalds cup.

Try again get them back or an easy DIY fix?


r/heatpumps • • 20h ago

Question/Advice Need sanity check on advice from heat pump company

4 Upvotes

My mother in law's house is about 3.5k sq feet with a larger heat pump downstairs and a smaller one in the attic for the upstairs, both installed about 3 years ago it is in a temperate climate with mild winters. Both units work fine in the summer, but there have been significant issues with the upstairs unit heating from the jump.

The initial problem was that the upstairs unit wasn't able to warm up sufficiently to actually heat the house if it was remotely cold outside and just blow cold air. The installers initial advice was to have the heater set for 75 or 78 degrees in the afternoons so that it would run and stay warm through the night, which is ridiculous because in no world does anyone want a home anywhere close to that warm.

After numerous calls to the company and visits, they ended up adding a gas line into the system to give it some extra power.

It's been working much better since, but they came in to fix something recently and are now giving my MIL some line about setting the temperature to something like 80 degrees for an hour or so in the morning to jumpstart the heat because it gives it an extra burst of power (and avoid having the heater running for 2-3 hours to get the temperature up).

I can't find anything online that suggests this is a good idea. It seems inefficient at best, and from a logical perspective it seems like having it run at that temperature when it's 55 degrees outside will give different results than when it's 40.

Is there any truth to what my MIL is being told? The more of this sort of advice we get, the more I worry that she has defective or improperly installed equipment.


r/heatpumps • • 16h ago

Question/Advice Heat sync - different room temperatures

1 Upvotes

Hi all, not sure if this is the best place to ask but we’re in a predicament with our heating system upstairs.

We have an upstairs thermostat (nest thermostat) and it’s connected to a heatsync. It provides heat to our office radiator and our bedroom radiator, and we can individually control the valves to turn them on/off if needed.

Problem is either:

  • thermostat in office, office heats up faster than bedroom because there’s a computer and maybe better insulation? This means bedroom stays cold because thermostat no longer requires heat after office reaches desired temperature (problem at night as bedroom is cold when we go to bed)

  • thermostat in bedroom, office still heats up faster than bedroom and provides heat unnecessarily. Yes I can turn the valve to switch it off manually at night once it feels warm but during the day it’s also wasted energy heating the bedroom that nobody is in. The bedroom heats up fast if the thermostat is in this room.

I’ve heard of a thermostatic radiator valve but don’t fully understand how it would work in my situation. Are there any smart devices that can help with this? We’re integrated quite nicely with Google home and home assistant but at the moment I’m manually moving thermostat to the office in the day then to the bedroom at night and I’m desperately looking for a more automatic / better solution.

Cheers!

TLDR

Can I set the office to call for heat during the day and the bedroom to call for heat before bed, while keeping the other radiator off or cooler?


r/heatpumps • • 1d ago

Question/Advice Oil Boiler Replacement Advice needed

3 Upvotes

Suffolk Long Island resident of a colonial-style two-story home , having an oil boiler for heat and water which is 28 years old. Have a 4.5-ton central air con 17+ years old with ceiling ducts. Confused if i replace the same separate units or go with a heat pump. No open issues but don’t want to wait till they break and with current oil prices things are getting worse. Need suggestions especially on the effectiveness of ceiling ducts for heat from a heat pump system and a genuine knowledgeable installer who avoids upselling


r/heatpumps • • 2d ago

Ecodan ASHP self-learning weather curve controller

Thumbnail
gallery
18 Upvotes

I have an Ecodan 11.2 kW in a house with a mix of underfloor heating and radiators. I never got the FTC's weather curve right. Too high and the COP suffers; too low and some rooms never warm up. Every tweak meant waiting days to see the effect.

So I built a controller that sets the flow temperature itself and learns from the result. It runs in Docker alongside Home Assistant, reads the temperature in every room, and adjusts the curve depending on whether rooms ended up too warm or too cold.

First sub-zero night this month: outside went from 3 °C to −2 °C, the flow rose gradually from 38 °C to 48 °C, and the house stayed at 20.2–20.5 °C. It had never seen frost before; by morning it had learned its own frost curve from that one night. The curve is now about 34 °C flow at 10 °C outside, 37 °C at 5 °C and 41 °C at 0 °C.

What's under the hood:

- Two curves, split at about 2 °C, because defrost cycles eat into heating time. It blends between them so there's no jump. Until it has frost data, the frost curve follows the normal one.

- Being too cold counts double compared with being too warm, so it never saves money by leaving you cold.

- Rooms are weighted. A cold living room matters more than a cold spare room, and every room still has a minimum it must not drop below.

- Solar gain is worked out properly. It learns what your panels produce on a clear day at each time of day, so it can tell direct sun from bright cloud. It knows which side of the house the sun is on, so only the rooms it's actually shining on get credited.

- Tariff aware (Octopus, or any supplier whose prices are in HA). It stores heat in the underfloor screed during cheap hours and coasts through the peak, but only while every room stays comfortable.

- It never learns from bad data. Sensor dropouts, restarts and mode changes are held through and left out of the learning. If the outdoor sensor drops out, it switches to a backup source. If everything fails, it doesn't change anything rather than guessing.

- Every write is checked by reading the setpoint back from the unit.

You need the Ecodan already in HA with a flow temperature it can write to, plus temperature sensors in your rooms. Observe mode runs for a week showing what it would set, without touching anything.

It isn't public yet. My own version also runs hot water, summer cooling, Solcast PV forecasts and battery load-shifting, but those are too tailored to my house to release yet. Yes, I built it with a lot of AI help, and it's been running my house for two winters.

Would anyone use it, to release it I'd need to do some work to make it transferable and easy to setup for another person so before I go to the effort thought I'd ask!? Some screenshots attached


r/heatpumps • • 1d ago

Ground source heat pump not working

3 Upvotes

Seeking some help with a ground source heat pump please.

I have the following:-

Mastertherm GSHP
Solar Thermal
Solar PV

Back about 6 weeks ago, the consumer unit tripped out. I put it back on and thought nothing of it as this has happened before. Anyway, I then noticed the hot water wasn’t working. At the time the solar thermal panels were providing the HW as we still had sun then. So then I had just assumed it was an issue with the solar and the hot water. The immersion is working fine so had just been sticking that on whilst awaiting someone to come look at it.

Since temp has dropped, I’ve now realised that the heat pump is not working at all. There is a display on top of the GSHP which does not come on at all. I am wondering if there are any cursory checks which I can do to see if this is something is can perhaps solve and get it up and running. I’ve got young children and so it’s a bit frustrating that it appear to have no power and won’t work 😫


r/heatpumps • • 2d ago

Question/Advice Help with heat pump / central heating issue please

4 Upvotes

We have a Samsung 7th Gen heat pump and the rads on zone 2 aren't getting hot for the last few days (has been installed for over 2 years).

Due to the weird set up in our house zone 1 covers a portion of downstairs and is pretty much always off.

I checked the filter on the pipe work near the heat pump and it was clean.

The hot water heats up no problem.

Zone 1 ran as a test without zone 2 on and heated up well.

The cylinder has 3 motorised valves (Honeywell silver boxes), when each section (DHW, Z1, Z2) is on the levers are loose meaning they are open (tested one by one with the others off). When the whole system is off the levers can all be pushed manually open, you can hear them open then the lever returns to closed and again hear it close.

There are two pumps on the cylinder, the primary running the water through the heat pump lights up, hums and gets warm to the touch.

The other one did the same when zone 1 was on however I don't think it is turning on when zone 2 is calling for heat possibly explaining the issue (the warm water is naturally rising enough to heat the first 3 rads a bit but not going any further).

Google suggest the motorised value is opening but not telling the pump to turn on due to a wiring failure failing to tell the pump to turn on and replacing that silver head on the motorised valve can be done without draining the system.

The suggested test was to put zone 1 and 2 on together, this would mean zone 1 motorised value has turned on the pump and zone 2 valve is open so the rads on zone 2 will now get hot which seems to be happening so we can exclude a blockage in zone 2 causing the issue.

Does all this sound right or is there something else I should be considering.

Apologies if the post is too long but hopefully it covers everything!

Thank you in advance for any advice.


r/heatpumps • • 2d ago

Bosch Heat Pumps in Maryland

2 Upvotes

Fellow Marylanders,

Give me the good, bad, and ugly on Bosch heat pumps.


r/heatpumps • • 2d ago

Please pleas help

Thumbnail
gallery
9 Upvotes

Hi. So about a month ago we had a Mitsubishi air to water pump installed. 1930s 5 bed house with some insulation.
I have absolutely no idea how to set it, spent hours on AI chat trying to figure it out but it’s totally beyond my capabilities.
So yesterday in the first cold snap (-5 South Yorkshire) I went to bed at 10am with £19 pounds on display. At this rate we will get bankrupt.


r/heatpumps • • 1d ago

[For Hire] Custom Website Development, Redesigns & SEO Services

0 Upvotes

Hey everyone! I'm a web developer specializing in custom websites, website redesigns, e-commerce development, and SEO to help businesses improve their online presence.

Here's an example of my work: https://nodoubts.ca

If you're looking for a new website or want to improve your existing one, feel free to DM me!


r/heatpumps • • 2d ago

Question/Advice water heater replacement and cost, is a hybrid heat pump tank worth double the price?

9 Upvotes

my twelve year old 50 gallon electric tank in the garage here in raleigh started rusting around the bottom pan last week, so i got a few local quotes. a standard 240v tank swap came back around two thousand bucks with permits, haul away, and an expansion tank, while a hybrid heat pump unit jumped to thirty eight hundred because of running a condensate drain line and extra prep work.

paying almost double upfront stings, so i plugged our monthly utility numbers into palmetto last night to see how much a heat pump model would actually shave off our power bill. their energy tracking tools show water heating eats up a huge chunk of our kwh usage, though an eighteen hundred dollar price gap still takes years to earn back even with local electric rates. i am leaning toward the hybrid unit since my garage stays warm most of the year anyway, even if the extra compressor noise and upfront hit make it a tough call.


r/heatpumps • • 3d ago

Heatpump running cost 😂😂

Post image
98 Upvotes

Ive had my heatpump installed and running 2 days now, 19th and 20th. 15.5kw grant in a 4 bed fully insulated stone farmhouse. Jfc. 19th was only on halfish day, 20 been on all day trying get house up to temperature. We are awaiting out g99 application for solar and battery but 130kw/day? We were using about 25/30 a day beforehand bar the last two weeks as we have been getting insulation/ashp installed. Is 100kw/day the norm going forward? Or is it because its just getting house up to temperature then it will settle down? Im just on a regular tariff as well till I fet my solar installed.


r/heatpumps • • 2d ago

Learning/Info 8 months of hpwh

Post image
7 Upvotes

Navian 50gal hybrid heatpump water heater, 2 adults, 2 young kids, set on heat pump mode @150f. At our current rate of 0.20/kw that’s about $108 to heat water for 8 months. If I had to guess we’ve run out of water 5-10 times, always when the wife is having an evening bath. Very happy with early results


r/heatpumps • • 2d ago

COP during recovery from temperature setback

3 Upvotes

I am looking into setting back the temperate to reduce cost/carbon under certain conditions. To help guide this, is there data or way to to figure out the change in variable heat pump COP near steady state for heating vs when the setpoint is much higher than actual room temperature, e.g. 10C actual 23C setpoint, outside -10C? Assuming constant electricity costs, no supplementary heating, and don't care about long time to warm up, could I expect to save a bit, any other reason not to do this? To be used e.g. overnight or when going away for a while, or a cottage used sporadically in the winter. Thanks.


r/heatpumps • • 2d ago

Montreal - Thermopompe broken and furnace is in attic

1 Upvotes

Hello everyone,

I am looking to replace my central heating system and my current setup has furnace in attic. The HVAC broke down after I fully renovated the place 😢. So installing it in basement is not an option as I have to redo ducting which will be very expensive.

Are there any options to replace furnace in attic and thermopompe. My current one is Kelvinator.

Thanks


r/heatpumps • • 2d ago

Question/Advice Emitters for heat pump

0 Upvotes

We are doing a renovation of a mid terrace in England. Wanted underfloor heating with engineered wood floors. We have got the results back from the heat loss study and with a design temp of 48 degrees we are looking to be below requirements in almost every room.
I’m quite comfortable at 22-23 degrees with my combi boiler and I’m looking at the paperwork suggesting I’ll struggle to get up to 21 degrees.
The problem seem to be the ufh but if I stuck with traditional radiators, I’d need to swap out for 2-3x the size and also add a couple of rads.

I wonder, am I reading these documents right? Or what am I missing?


r/heatpumps • • 3d ago

Heat pumps can heat homes for €2.20 a day in winter, study finds

Thumbnail
euronews.com
154 Upvotes

r/heatpumps • • 2d ago

Question/Advice Swap out non-HyperHeat units?

3 Upvotes

We added a dual-zone Mitsubishi minisplit system to the second floor of our home in Rhode Island during a recent renovation: a 6K head-unit in each bedroom. It's not HyperHeat.

We're now adding Mitsubishi HyperHeat units on the ground floor. We hope to no longer use our oil-fired furnace.

Should I swap the upstairs, non-HyperHeat models for HyperHeat units? The HVAC contractor says it's not worth it: that the spray-foam insulation that was installed during the renovation, heat rising from the ground floor, and the performance of the upstairs units will keep those upstairs bedrooms warm in winter.

For reference, the compressor for the upstairs units is MXZ-2C20NA4.


r/heatpumps • • 2d ago

Question/Advice Mini split for just the room over the garage or go ductless everywhere?

3 Upvotes

It's a two story, about 2,000 sq ft in eastern PA, vinyl siding over 2x4 walls and older double pane windows. The room over the garage hits like 85F in summer and drops to the low 50s F in winter, while the rest of the house stays around 68F.

I tried a booster fan in that vent and sealed around the garage ceiling, and it helped a little.

I'm thinking one mini split in that room fixes it and the furnace and central air keep handling the rest. Is one zone enough here or does it make more sense to do the whole house at once?