r/heatpumps • u/i_am_qnsblvd • Feb 22 '26
Heat pump just installed slightly off level. How serious is this?
I’m going to talk to the installers but wanted to get an idea on seriousness of it before I do.
r/heatpumps • u/i_am_qnsblvd • Feb 22 '26
I’m going to talk to the installers but wanted to get an idea on seriousness of it before I do.
r/heatpumps • u/Interwebnaut • Apr 07 '25
r/heatpumps • u/xtnh • May 31 '24
We live near Lawrence, Mass. and know people whose homes blew up or burned when the gas utility did an oops and ruined hundreds of homes.
Research shows that burning gas in the home affects kids' lungs. The warning labels on propane is :don't use indoors!", but natural gas s fine?
Natural gas smothers people in their sleep.
If someone said "We will give you $300 a year if you let us ope in a substance that could kill you in your sleep, blow up your house, and all affect your kids' lungs", would you let them do it?
r/heatpumps • u/foggysail • Jan 10 '25
OK, some will say if your heat pump matches a Manual J predicted requirement, don't oversize. I did my own Manual J using a spreadsheet rather than a program. I also had 3 bidding companies provide so called professionally done Manual J's. All including mine agreed within about 1K BTUS or so using a delta T of 65F.
My system:
Upstairs uses a MXZ-SM36NAMHZ-U1, downstairs a MXZ-C30NAHZ4-U1.
The 36KBTU works flawlessly regardless of the outside temperatures with so far a low of 10F. Not so with the 30KBTU system! A system that required a Mitsubishi software update during December! At temperatures below about 20F we find the thing going into defrost too often for it to get our rooms higher than about 72F while we want 75F. In fact, IT GETS CHILLY during defrost as one should expect in this mode. Remember, the refrigerant is reversed during a defrost.
OK, so the $#%^& thing works fine above 20F what is wrong with that? How often do we here in Massachusetts see temperatures below 20F with the welcomed so called global warming?
I am soo friggen disgusted with this dog I am considering replacing it before next winter with the same model used for the 2nd floor. Time will tell, we have many days between now and the next cooling season..
One last note.... I highly suggest to all who read my frustrating post to consider the benefits of oversizing. James Cummings & Charles Withers of the Florida Solar Energy Center have posted documentation ''Making the Case for Oversizing Variable-Capacity Heat Pumps!
Those who continue to claim ''thou shall not oversize'' are posting plain bull poop!
EDIT--- gees, I expected more negatives by now, only 1 so far.
r/heatpumps • u/gotshroom • Mar 16 '24
r/heatpumps • u/chris2355 • Mar 19 '25
Hi all,
Do you like saving money? I do, I want to buy a heat pump using r290 (refrigerant grade propane), they're available all over the world, but not in the US.
R290 is a byproduct of natural gas and petroleum production. The current charge limit is 500g for commercial refrigeration, enough for a freezer, but not a heat pump that will heat your home, hot water including old school cast iron radiators. It can also cool your house with hydronic fan coils (wet mini split).
The heat pump in monoblock form keeps all the combustable materials outside your home and they are far less likely to leak (refrigerant, water, carbon monoxide all the bad things).
Do care about global warming, if so, it has a gwp of 3 (only thing lower is CO2). If not, you probably want to only have to pay for labor for a single system and save $$$. It's also pretty easy to diy, as it's a sealed pre charged unit, you only connect plumbing and hard wire it (15 to 20A).
What new trump administration official does the Reddit mob need to direct its attention at on X/Twitter/truth social? I want progress and I want it now...
I'd like to replace my heating system this spring/summer. Payback periods with time of use rates even with low cost per therm can be very quick particularly if you DIY it.
r/heatpumps • u/goldserve • May 22 '25
For a little more context, I am looking to heat/cool a space of around 1800sq feet with good access in the attic to install everything. This will be a remodel project so from scratch.
I asked for ceiling cassette Mitsubishi for individual room control and a forced air to service the one large kitchen and living room area.
This one company came back with the following:
3 ton condenser - MXZ-SM36NAM2
2 ton air handler, mid static in attic - PEAD-A24AA9
9K ceiling cassette for one bedroom - MLZ-KP09NA2
6K ceiling cassette for another bedroom - MLZ-KY06NA
New ductwork (1 return 6 supply) for living room and dinning area system
Attic package if electrical and access is not present
Permitting
Total: 37K
Now, does anyone have personal experience with other companies that I could reach out to for a more reasonable quote, servicing the peninsula? Please DM me! Thanks!
r/heatpumps • u/woburnite • Dec 15 '24
I am used to baseboard/HW heat, and this is my second winter in a rental with a cold weather heat pump. First winter I had all kinds of problems, they got fixed; this winter there was a leak, that got fixed (maybe). But in general, the heat is not even, when it starts up it blows cold air around the room until the heat kicks in, it's very drafty (fan is set on low). The corner of the house farthest from the inside unit (bathroom) never gets warm. Heat in the room with the unit goes from 60F to 70F.
IOW, it seems it is not a steady, reliable heat. I don't think I would choose it if I was building a house. Am I doing something wrong?
r/heatpumps • u/renerenerene25 • 12d ago
I’ve been reading more about heat pumps recebtly and noticed some cozeware mini split models offer both heating and cooling. I’m curious how well they actually work throughout the year. Do you use yours as your main heating and cooling systemm?
r/heatpumps • u/fleecerobot • Mar 02 '26
When we bought our home it had a 50 gallon AO Smith condensing gas water heater from 2011. It started intermittently not working, and slowly leaking, so it was time to replace it.
It had worked great, we have a 400 sq ft radiant heated floor, and 5 people, and had never run out of water.
We replaced it with a 65 gallon Rheema Proterra Hybrid Heatpump water heater. (the largest size we could fit). It doesn't have enough capacity, attempting to heat the 400 sq ft area on a 75 degree day, with no showers or dishwasher or laundry, makes the tank empty according to the app.
- In Heat Pump only mode it will never refill until we turn off the floor and wait several hours. In High Demand or Energy saving mode it will use 30-40 kWH/day, which at our electric rates is $15-20.
- We live in the CA bay area
- Our water heater is in an external room that barely fits it, but has a 3x2 screened window. That room gets down to 45 degrees when it's 75 out with the heat pump. I could try to add a fan to the screened window?
- The radiant floor is in our home office, it's the only heat we run during the day. So we'd like to keep using it.
My first thought was that it would be ideal to add an on demand gas water heater after the tank Heatpump waterheater, but my initial research said those don't work well with hot input water. I'd love to hear of any products that would work for that, or other ideas.
Thank you!
r/heatpumps • u/Optimistictumbler • Mar 21 '25
Our bill is around double to triple for electricity since we moved from a gas powered heater to a new heatpump powered by electricity. We do live in an area with very expensive electricity. Can we expect to see AC bills in the summer that are half of what they use to be with the conventional system? Will our average expenditure for the year end up being the same or less…or more?
The way we have the system running is downstairs is on, and upstairs never turns on because currently no one is spending any time up there. Is this method making our heating more expensive?
Dad of the house is also consistently lowering the temp on the downstairs unit to try to save money. Is this chasing warmer temps for the next block of time several times each day, causing higher usage of electricity and lengthening heating time overall?
Location: Coastal CA. Lows at night are around 45, daytime temps average 65-72.
The heatpump was not my decision. I got vetoed.
r/heatpumps • u/donttayzondaymebro • Nov 12 '23
I don’t understand how a heat pump could be more efficient. I’m sure there are other advantages to a heat pump over electric heating element, but on an efficiency level, it seems electric elements are more efficient.
r/heatpumps • u/ClavenEstine • May 10 '24
Hi everyone,
I have some serious problems with heat pumps and would like to know what the community has to say about my concerns.
I live in Vancouver, British Columbia, Canada, but my concerns could be applicable to just about anywhere.
BC Hydro imported nearly 10,000 gigawatt-hours of electricity in 2023—around a fifth of its total load—at a cost of more than C$450 million. So, if I, and even 50% of the other 4 million citizens all install heat pumps to save the planet, where is all the electricity going to come from? ?? (We are in a drought right now so new dams are probably not going to be built anytime soon)
My natural gas furnace has been running for 40 years without ANY problems except for regular cleaning, filter replacement and pilot light replacement. Can I expect this heat pump is going to give me the same life and low cost maintenance??
$15300.00 To $19550.00 is what I was quoted to install a new heat pump. (Canadian cost, so about $15,000 for you guys in the US (Probably the cheapest system they have, so if I do some research I expect the cost will go up dramatically) Add to that the cost of borrowing this at today's interest rate and I think you can see my reluctance to swap out my system. Any thoughts??
Right now I pay $136 per month for natural gas to heat my home. (averaged over the whole year) My cost to borrow the $20,000 for 5 years @ 10% is $450/month. Add to that the increase in electrical rates due to the heat pump and it becomes a really difficult burden for us. Again, thoughts??
Thanks for listening
Claven
r/heatpumps • u/CaffeinatedAmazonian • Dec 26 '24
I have a brother that lives in Missouri and has no electricity (got shut off). He’s in a remote area, but I can send him things. What kind of small camping heaters could run off a USB port? Apparently the type of charging station he has would allow for that. He goes to a church and the pastor lets him charge the station a few times a week. He’s using a propane heater currently when it drops below 20°. I plan to bring him out here in May. I just want to make sure he will be okay through the winter. And I’m worried about him using the propane heater.
r/heatpumps • u/[deleted] • Mar 03 '26
Hello, so I've been solving an issue where the neighbors heat-pump creates disturbing low-frequency rumbling noise during the winter. And some higher pitch wuthering/ whizzing from their air-conditioning during summer that's right next to the heat-pump.
This noise during the winter is impairing my sleep. Here's some of our experiences if it is of help for anyone dealing with a similar situation.
We've made progress by taking measurements with a calibrated dB-meter and discussing the thing with the neighbor and also reading up on the local laws. Since the noise during winter is of such low-frequency, it doesn't break the dBA sound limits inside the home bedroom during the night. But it does break the national dBC limits at multiple frequencies by more than 10dB, measured from inside the home bedroom.. These are different limits specified in the law. Also, there are limits to how loud it is allowed to be outside, this limit is also broken at the dBA level outside at the property border.
Don't get me wrong, just because the noise only breaks dBC limits doesn't mean it's not very disturbing! It sounds like a diesel truck idling outside.
Since the neighbor is somewhat receptive to discussing solutions, we are working together with an acoustics engineer to figure out what the solution will be. The best, most reliable and simplest solution in most cases is to relocate the heat-pump/pumps further away. But since this is often costly and the neighbor usually places it where they do for their own visual/convenience benefit, they usually will not want to do this.
The most likely solution will be a thick concrete wall, located in such a way that it reflects the noise away from your house, preferably away from anyone's house! Possibly with a roof above, so that the noise won't travel over the wall. (Be careful of possible reflection back again to your house! The sound can bounce from the barrier back onto their wall for example, and then still be reflected over the wall to your bedroom. The solution here would for example be a roof that is connected to the barrier, this would force the sound to escape to the sides, not above the wall.).
Of course, if they aren't willing to accommodate this solution, we might have to take matters to the local regulatory agencies. In the worst case, they might have to move the units somewhere else, since they exceed the regulations (both inside the bedrooms closest and outside at the property border).
But try to keep as professional, kind and understanding as possible even if the matter can feel unfair. Working together will do more good than having poor relations.
And a solution that both of you are happy with is the goal here. Regulatory agencies are there if no solution is found and the problem is still very disruptive.
So, for anyone else struggling with a similar situation, here is some advice:
-Tell the neighbor that the noise is disruptive and what the disruption is, and tell them that you should discuss a solution to the problem at a future point (this, to make them aware of the issue ASAP and let them process the emotions connected to this already before serious discussion is done).
-Rent a calibrated, official sound level dB-meter, with a calibration certificate from an official company that does professional measurements, take measurements over the whole night, when the unit is on and making disturbing noise. Also take measurements at different locations (inside house, bedrooms, property border, outside windows). Make sure the measurement device also records both dBA and dBC + creates recordings for the whole time of 5-minute average levels (dBAeqf 5 min, dBCeqf 5 min). Save the measurement data to be used for later on your computer. To be able to compare to regulations. This will help the acoustician understand the nature of the issue and also help with explaining the issue to your neighbor.
-Read up on your local regulations and laws, check the details for all different scenarios: outside, inside, bedroom, night-time, day-time, at property border, outside at property and based on if your property is in the countryside or city or suburban areas. The limits to each case is usually different (at least in my country that cares about peoples well-being). Check both dBA and dBC level regulation limits. This is a concrete, factual point to fall back on if your neighbor isn't understanding or cares about the disruption caused.
-Talk with or hire an acoustics engineer to take a look and think about the situation, the specifics, the measurements, the property schemas, wall composition, sound characteristics etc. Ask the acoustics engineer to make a statement, to give advice on how the sound would best be dealt with. (what composition of wall, what barriers, what distance, what wall-composition, possible sound-dampening materials etc.). Also ask the acoustics engineer about if they know how the law treats these cases of violating regulations of noise levels, in case things come to that.
-After you have concrete measurements and evidence and have read up on possible regulation violations and you have consulted with an acoustician/ acoustics engineer, then you can take the matter up for discussion with your neighbor and refer to what the measurements are, what the regulation says and what the acoustic engineers statement is.
-Now try to come up with a solution that doesn't require the heat-pump to be relocated if possible, a solution which the neighbor also would be happy with. See if the acoustics engineer approves that a wall of a certain thickness and material would likely fix the issue. If the acoustician/ acoustics engineer says that nothing can be done except relocate the unit/s, then you can contact the relevant local regulatory agencies for a more forceful approach if you want to go down that path.
Good luck, take one step of these actions at a time and hold on tight. I know how incredibly frustrating dealing with this issue can be, since it feels like you are powerless to enact change. It impairs sleep and peace at your own home and during sleep, where you are supposed to feel safe and be able to rest. So it feels like an assault on your life. Try to stay calm and collected, be respectful with your neighbors and deal with it through the objective, factual path. By taking measurements, checking on regulations, consulting an objective acoustics engineer and then if it still isn't solved, contact the regulatory agencies.
It's unfortunate to be in a position where either you have to be unhappy and suffer or your neighbor has to be unhappy. So it's a tough situation, I hate to have to deal with it, it's stressful to live with it and stressful to try to find a solution!
Good luck, you can get through this!
Edit: I understand that this topic is inflammatory for many who are planning on getting their own heat-pump or have their own heat-pump. But I ask you to consider this from the perspective of people disturbed by them. How would you feel if suddenly a neighbor installed a heat-pump outside of your bedroom, 12 feet away, and you hear a loud rumbling every time you are in the room trying to sleep. You spent 100's of thousands of dollars and years building and paying off loans on this home to have a place for peace and quiet, and suddenly the equivalent of a diesel-truck idling is outside of your bedroom every night for 4 months of the year.
Of course heat-pumps aren't bad in and of themselves, but you need to be mindful of the possible noise-pollution they can cause. Especially to neighbors. People tend to position the unit in a way that it bother them, but the neighbors never expected such a noise-disturbance when they built or bought the property. Before installing one, it's easy to locate it in a way that doesn't bother others, after installing it's much harder to deal with any arising issues.
We've been very respectful and accommodating for them so far in all other matters.
Try to work together with your neighbor for a solution that you both are happy with. Only if no solution has been found for a while even after trying to discuss with your neighbor, and the problem is still very disruptive, should you consider taking up the matter with the HOA or regulatory agencies.
r/heatpumps • u/Moto_823 • 17d ago
I see this question posted alot, I felt it was easier to illustrate this using AI than to try and hand write out the math.
Especially becomes a factor of $/kwh delivered vs oil cost, and then figuring the average COP of the equipment you choose.
Most oil furnaces are around 85-87% combustion efficiency.
Ducted heat pumps 1.8 - 3.8 COP depending on outdoor temperature , make, model, features.
Variable speed with Variable speed compressor will operate the most efficient in low temps.
there's alot of rebates that help make the installation cost a little more affordable. Hope this helps.
r/heatpumps • u/Deering_Huntah • Oct 07 '26
Good evening,
mods or algorithm may hide this post but I believe it is very important for public health to mention below: I have installed over a 200 heat pumps. And I'm lately finding that any pump with some kind of horizontal drain creates a mold/black mold habitat. In my house it was so severe that I replaced the entire fan wheel and sanitized the whole unit. There isn't enough education about this risk and the local companies will not correct it with the annual “ cleaning”. Feel free to dm for details.
r/heatpumps • u/clutchied • Sep 19 '24
I did a quick energy check on Energy Vanguard with their spreadsheet. Pretty helpful and added some insight on why people with heatpumps in colder climates are so frustrated by the cost of their electric.
It seems to me the heatpump crowd isn't being totally honest about the costs surrounding these systems. Yes, HPs are more efficient. Yes, they are better for the environment. No they aren't necessarily cheaper which is totally related to the energy density and cheap cost of natty gas.
When I ran my local numbers $0.15 / kWh for A/C and $0.039 / kWh equivalent of gas... Heating w/ gas per equivalent kWh is 4x cheaper.
With that being said I don't think my heatpump would burn 6800 kWh's in a month to the 231 therms I used but it does give some insight into costing and how these formulas can shake out depending on location.
in transparency I have an OLD 70% efficient furnace and I'm going to be going to a hybrid HP/Furnace setup in the future. I also have solar so the electric costs are moot and only add to my return.
SW Ohio, 4900 sq. ft. R60 in the ceiling. 70% efficient furnace. 5 ton A/C from '05. I use gas to heat water, dry clothes and heat the house.
Here's the schedule.
r/heatpumps • u/scotchmckilowatt • Jan 15 '24
We spent a week in a very mild part of the country with my in laws and like everyone else here they have a massively oversized forced air gas furnace in a fairly leaky house. By comparison, we have an undersized heat pump in a northern climate (our home is well-insulated, ventilated, and close to 1 ACH50). We have been living with the heat pump for just under a year.
My FIL turned on the furnace early this morning to take the chill off before we caught our flight home and my god it was jarring. I couldn’t take it. The too-hot heat blasting into the bedroom, the noisy airflow, the general unevenness of temperatures due to shorter cycles (there are still some cooler spots in the house). I knew the theory behind all this but it’s another thing to experience again after living without it for a while.
I know it’s not the fuel source per se that makes the difference but since furnaces don’t come much smaller than 60kBtu I feel like heating with it is a crime against the laws of thermodynamics. Anyone else find they cannot tolerate homes with gas forced air now?
EDIT: yes as many have pointed out this isn’t a true apples to apples comparison as modern modulating and variable speed fan gas-fired equipment exists. But it definitely represents a norm in the mild climate area where my FIL lives, which unlike many parts of the country is a slam dunk for electrification
r/heatpumps • u/clumsyninja2 • Jul 01 '26
Is this to protect the unit somehow?
I've noticed that when the outside temp is hotter than 90f and you try to call for heat, the unit will not react, even if indoor temp is 70 and I'm trying to set it to 86f.
Does anyone know why?
r/heatpumps • u/aegiswings • Nov 27 '23
My central AC broke down this summer and I decided to replace it with a 2.5 ton heat pump. At the same time I replace my gas furnace with a new 96% efficiency one. The heat pump is fairly efficient (COP 3.4 @ 47F, 2.8 @ 17F) and I was told I could run it down to 15 F although the economic break even point was probably higher. What I didn't realize was how much higher it actually was.
Well the temp averaged 47F out last month and my electric bill was ~$225. I should have done the math but at least I have the gas furnace to use for the winter instead.
If you are thinking about a heat pump in a cooler part of the country, especially Massachusetts, I'd reconsider it, unless, perhaps, you are switching from oil heat.
FYI, my electric is $0.32/kwh and gas is $1.75/therm. For me to break even on a heat pump, the efficiency (COP) would have to be >5, which doesn't exist for a heat pump! So at no temperature is at heat pump cheaper. Even with a COP of 4, it would only make sense at temps >65 (at which point you are not running heat).
I am in the process of switch electric providers which would lower my electric to ~$0.29, but my electric would have to be half what it is now for me to see any savings. With delivery charges at $0.16, that is never going to happen.
Good news is a state program gave me a $2400 rebate for getting a heat pump which basically compensated for the additional cost over an AC. Too bad I'll never actually use the heat pump, though.
r/heatpumps • u/Outrageous_Job_1930 • Jul 29 '25
r/heatpumps • u/Interwebnaut • Mar 18 '25
r/heatpumps • u/No_Baseball4229 • Jan 30 '25
Hey so I just got a new heat pump and panel upgrade and my bill shot all the way up to 770 dollars from 200 a month and I’m just so confused and I really really need help with this. The guy who installed everything has honestly lost my trust I feel like something is definitely wrong!