r/firePE • • 22h ago

A browser fire pump room: NFPA 20 curve, cavitation, and 12 sprinklers

43 Upvotes

I built a single HTML file that opens a 3D fire pump room in the browser. No install. Three.js.

What is in the room: an electric fire pump, a diesel backup that starts on power loss or runs in parallel at high flow, a jockey pump, NFPA 20 controllers, a UL-142 diesel day tank, a break tank, a wet alarm valve, an outdoor hydrant, a Siamese fire-department connection, and 12 ceiling sprinklers.

What you can change:

- Pump curve against system resistance. Parallel pumps share flow as speed changes. Discharge pressure is suction pressure plus pump head. Shaft power uses the differential pressure.

- NFPA 13 Hazen-Williams friction, DN25 to DN150.

- Clog the strainer or throttle the suction valve and compare NPSHa with NPSHr.

- EN 12845 classes LH, OH2, and HHS2. Bulbs at 57, 68, 79, and 93 C, quick or standard response, with an Alpert ceiling jet and RTI.

- Test drain or open heads drop the tank level, in real time or sped up.

The screen carries this line: Informational & educational purposes only — not for engineering design. The formulas were reviewed as teaching relations. I would not use it to size a real pump.

https://www.meptasarim.com/fire-sprinkler-simulator.html

If you design to NFPA 13 or EN 12845, which part of a teaching model like this usually goes wrong first?


r/firePE • • 12h ago

NFPA 72 2025 - Genuine?

Thumbnail
gallery
2 Upvotes

Using this book in office and just trying to make sure it’s genuine. I use NFPALINK for the digital version so I’m gonna be double checking to make sure it aligns, just prefer physical copy and unsure of the source of where this was originally purchased.

-All pages have this NFPA logo in the middle, is that typical?

-do the front and back look correct?

I have nothing to compare to in real life, this is the only office copy!

Also included are my NFPA 70 pictures, if someone can possibly verify just by picture, again will double check codes match NFPAlink…
This one was questionable because it’s my first time seeing a foil logo. Which is only on the NEC and not the NFPA 72.

TIA!


r/firePE • • 13h ago

Was told this is okay—is it?

Thumbnail gallery
0 Upvotes

I’m not sure which sub is better for my question. More info on the other post but I live in a 50 unit condo. State is NJ. Recently HOA had to update the building fire alarm system as the old one was 25 years old. New fire pulls are larger then the old ones so it doesn’t fit. The box can’t be moved to the right because there’s a steel beam there (steel beam seems to go up and around the 3 pane French door system to the patio).

The technicians wanted to cut into the door frame to the left on the photo and install it inset into the frame. That just seems…wrong.

After I started to research, it seems the location behind where a door opens isn’t right anyway. I’m trying to get them to move it to the other side of the door where there is ample space—even at my own expense.

I used chat gpt to try to show what they wanted to do. They were really trying to force me to just agree so they could move on. Is this to code/safe? The photos are in the other post. It’s a kitchen pantry door to the left and it stands open half the day because my kids go in to get a snack and just leave it open. So even the old fire pull frequently had an open door blocking it.

If this were your house, would you want it relocated or would you be okay with it installed into a cutout of the door frame, and behind a door that is frequently open?


r/firePE • • 7d ago

PHMSA wants to replace two decades of NFPA 59A editions in one rule

0 Upvotes

A report from the National Law Review says PHMSA has proposed incorporating the 2026 edition of NFPA 59A by reference into 49 CFR Part 193, replacing the 2001 and 2006 editions that LNG facilities have designed against for close to twenty years. The current structure splits fire protection, security, and cathodic protection requirements across separate subparts, with fire protection getting its own dedicated section. The proposal folds that subpart and several others into one structure built around the 2026 edition, treating those three areas as a single set of requirements instead of three.

Once an edition swap like this lands, the open question for every existing LNG facility isn’t whether its fire protection system was designed correctly. It’s which edition it was designed to, and whether that still matches what’s enforceable. That check doesn’t happen automatically. Someone has to confirm it, facility by facility, before a submittal built on the 2001 or 2006 edition can be called current.

For broader background on fire-safety standards and regulations, see Mitti’s fire safety overview. It includes NFPA among the standards and regulators discussed.


r/firePE • • 7d ago

Hey fellow georgia state technicians Is anyone interested in working as a sprinkler service technician

0 Upvotes

The job is in Atlanta or perry for 30-40$ an hour and a 2500$ sign-on bonus for experienced techs if you want more détails dm


r/firePE • • 8d ago

NFPA pro board certs to college credit?

1 Upvotes

Just curious, looking to get a bachelors degree and I’ve been on the job for 10 years. I get some benefits with the military which will make getting a degree much easier/cheaper. Is there a way and or a school/program that will transfer proboard certs into college credit. I have FF 1, 2, NFPA 1021, 1041, 1521, and some extra NIMS classes (300, and 400). Just wondering if I could get credits for these classes and make getting a bachelors in Fire Science much quicker.


r/firePE • • 9d ago

Question on Sprinkler Pipe Hangers

5 Upvotes

I have recently passed a fire sprinkler design class and became a design trainee. I have been reviewing product data sheets for an upcoming submittal and noticed a 3/8ths top beam clamp is only rated for 500lbs on average. I started thinking and did the math. 4” schedule 10 steel pipe is roughly 11.7 lbs/ft. If you adhere to the requirements of NFPA 13 2025 17.1.2, you can only support 4ft of 4” schedule 10 because 4ft x 11.7=46.8 then 46.8 x 5=234 then 234+250=484lbs, which is just under the rated load-bearing capabilities of the 3/8ths beam clamps. I’ve seen 100’s of systems that have 4” schedule 10 being supported by beam clamps at much larger intervals. Am I missing something or are most designers not adequately supporting their systems?


r/firePE • • 12d ago

MeyerFire vs SFPE

4 Upvotes

I have a MeyerFire subscription with PE prep included that is paid thru work. Does anybody think this is enough or should I shell the ~1800 for the official SFPE prep as well?


r/firePE • • 12d ago

PDH Requirements for Indiana PE

2 Upvotes

Hello all,

New to reddit and a new PE in FP. I am trying to figure out if CEU's and such from vendors like AFSA and NFSA will count towards the PDH requirements for PE renewal in Indiana.

AFSA and NFSA, as an example, are not listed on the pre-approved vendors list for Indiana. Indiana Code IC 25-1-4-0.2 says that an approved organization refers to "(7) A national organization of practitioners whose members practicing in Indiana are subject to regulation by a board or agency regulating a profession or occupation under this title." Would these two vendors fall into this category and satisfy the requirements of professional development hours if I were to attend their training courses? Hoping a PE in Indiana can weigh in on their experience.

From my limited research it seems like the online PDH providers only offer generic courses and not so much specific to the fire protection field. I understand that a couple of your PDH's have to come from an ethics course and Indiana specific state law. My renewal isn't until 2028, just looking far ahead and want to plan some courses.

TIA!


r/firePE • • 13d ago

FPT COOP

1 Upvotes

Hey everyone!
I’m currently in my 3rd semester of the 3-year Fire Protection Engineering Technology program at Seneca, and I’m starting to think about co-op opportunities and job prospects after graduation.
I just wanted to ask anyone who’s currently in the program or has already graduated:
How difficult is it to land a co-op placement?
What kind of companies usually hire FPT students?
Is it possible to get a part-time or entry-level job related to fire protection while still studying?
How are the job prospects after graduation? Is it relatively easy to find a job?
Any advice on what certifications or skills I should work on to improve my chances?
I don’t have a driver’s licence or CFAA certification yet, so I’m also wondering how much that affects my opportunities.
I’d really appreciate any advice or experiences from current students or graduates. Thanks!
TORONTO,ON AREA


r/firePE • • 13d ago

Title: I’ve been a sprinkler designer for 15 years and built a tool to automate head layout. Looking for honest feedback from other designers.

0 Upvotes

Head layout on big ACT jobs always ate my time, so over the past year I built something that takes the RCP as a DXF and places heads by NFPA 13 spacing rules. It’s not perfect: some rooms still need tweaking.

A handful of designers are testing it on real jobs. If anyone wants to try it free and tell me where it falls short, I’d appreciate it. Happy to answer questions about how it works too.

visit SprinklerForge.com to sign up for beta.

Thank you


r/firePE • • 15d ago

In general, are heating devices that are turned off on their own switch still fire hazards if they are still plugged in at a socket that is on.

3 Upvotes

Specifically i am talking about an electric heating blanket. Are they firehazards even when turned of?


r/firePE • • 16d ago

Looking for advice as to what ENFP grad classes to take for Spring 2027

Thumbnail reddit.com
2 Upvotes

Any help would be appreciated!


r/firePE • • 17d ago

Reason for this Setup?

Post image
2 Upvotes

r/firePE • • 18d ago

Reg 4 test prep—any tips or practice tests?

1 Upvotes

I completed the Reg 4 orientation last month and am currently reviewing the manual. I work in fire protection doing inspections and testing, but I’d appreciate advice from anyone who’s taken the tests.
Are there any practice tests, study guides, or other resources you’d recommend? Was studying the manual enough, and are there specific topics I should focus on?
Any tips on preparing and what to expect would be appreciated. Thanks!


r/firePE • • 20d ago

Maximum distance for PIV valve

1 Upvotes

I’m reviewing a firewater main layout and looking for clarification on the placement of sectional isolation valves (like PIVs).
I am aware of the NFPA 24 requirement that no more than six fire protection connections can be isolated by a single break. However, aside from this connection limit and specific structural boundaries (e.g., water crossings, routing under buildings), does NFPA 24—or any other related NFPA standard—dictate a maximum physical distance/pipe length between sectional valves on a looped main?
I'd appreciate any specific code references or insights into how you handle valve spacing on very long pipe runs where the connection count is low


r/firePE • • 21d ago

NICET certification from EU

2 Upvotes

Hello, as I do not live in US and been wanting to get a role for remote position I learned that NICET certification is a must. Upon some reasearch I want to apply for NICET Water-Based Systems Layout Level I as it is the only level that can be held online. so here are my questions:

  1. Are all questions Multiple-choice?

  2. Are answers provided with SI units as well or only Imperial?

  3. If I take the exam online how can I use an NFPA online book? As my screen will be monitored at the time of the exam.

  4. How should I practice as I know and read NFPA 13, 14, 20, 22 and others is there more material to it? Do you know any online courses I can take? What would you recommend?

  5. For level II and above some Pearson VUE locations are available in Europe. Has anyone here been there and taken the exam from Europe? If I get the job with level 1 certification as well will the company finance trip and certification fees to Pearson VUE exam locations?

I have 3+ years experience, currently working as Senior Fire Protection Engineer and I have delivered 15+ residential, 5+ storage with 1 of them being 40,000 square meter / 430500 square foot, 1 mall (huge but I don't rememeber the area) and several multi-complex buildings with restaurants, pools and saunas, merchantile and other occupancies. As my country does not have its own standard we use NFPA for almost any big project as the authorities will approve project in compliance with NFPA.

I need your recommendations and experience to get a better knowledge of whats happening in overseas. Nicet exam tips are very welcome.


r/firePE • • 22d ago

Furniture spacing recommendation

Post image
1 Upvotes

Hi all. I was wondering if anyone could recommend the safest minimum gap I can have between my radiator and this piece of furniture. This is the only part of the radiator that’s “interacting” with furniture. I also rarely have it on - maybe 2-3 days per year.


r/firePE • • 25d ago

Need 3 more Android testers for a free MN journeyman sprinkler fitter exam prep app

1 Upvotes

I'm a fitter in Minnesota and I built a free study app for the MN journeyman sprinkler fitter exam. Google won't release it on the Play Store until 12 people test it for 14 days, and I'm at 9. It's Android only. If you can help:

  1. Join https://groups.google.com/g/mn-journeyman-exam-testers/about with the Google account on your phone

  2. Opt in: https://play.google.com/apps/testing/com.mnfireexamprep.app

  3. Install it from the Play Store

  4. Keep it installed for 14 days

Feedback welcome, good or bad.


r/firePE • • 25d ago

Animal Shelters - Fire Sprinkler Systems / Calcs

6 Upvotes

Having conversations about animal shelters and what hazard classification to identify them as for my calculations.

We typically always do OH1. Do any of ya'll run these animal housing facilities at OH too more often than not? I know it's ultimately up to the AHJ, just wondering why I'm always advised to calc and design per OH when NFPA 13 says LH.

Trying to look through multiple sources that are not AHJ amendments.

Opinions? Is it just because we love the animals too much? <3


r/firePE • • 25d ago

Fire sprinkler inspectors

Thumbnail reddit.com
1 Upvotes

r/firePE • • 25d ago

AI impact in FPE

0 Upvotes

Hi all,

How is AI impacting your work? To me it’s reducing significatively the amount of hours I need to accomplish my task and I’m wondering if this may cause a massive lay off in the near term

How’s been your experience so far ?