r/HVAC • u/Icy_Fig_3788 • 17m ago
Field Question, trade people only Brazing
Want are yall doing with left over braze rods? I got some left over and wanna see if anybody does anything cool with them
r/HVAC • u/Icy_Fig_3788 • 17m ago
Want are yall doing with left over braze rods? I got some left over and wanna see if anybody does anything cool with them
r/HVAC • u/Bdogfittercle • 24m ago
apprentice comes to work the other day and says he needs a pressure switch for his Grandpa's furnace. I ask why, he says the pressure switch isn't making. so went down the whole list, do you have a manometer, check this, check that. I guess they changed out the inducer last year there were some nuts in it and a squirrel. he took grass on the side, city was trying to blow his backpack blower down the flu with a shopvac on the other end, said he was getting air through it. I told him I guarantee you the thing is going to have a bunch of shit inside. told him to pull the front cover off and see if it'll run, it wouldn't. told him to pull the flu off and see if it'll run, and it did. I told him well, start cutting. he sends me this picture that night. he wears a size 12 just for reference.
I haven’t worked on oil furnace as much. The area I was at before had natural gas furnaces pretty much everywhere. Any tools that would make my life easier would be appreciated.
I've been to Atlanta airport a million times. I've never seen these ducks. But holy cow, this is something else.
Sort of makes me think of Carnival Cruise Lines red Whale-tailed exhaust stack that hides the engine exhaust, but just looks like a whale tail.
Thinking of picking one up to make transitions on site.
r/HVAC • u/JuicySpark • 20h ago
r/HVAC • u/VirginSubpoenaColada • 1d ago
I hear this especially in those advocating for 4 inch filter cabinets. Now don't get me wrong -- I'm all about 4 inch filters. And low static pressure is always a good thing. But has anything really changed that makes the equipment more sensitive to static pressure? In many ways, the opposite seems to be true.
In the case of constant airflow ECM blowers, I've been told they can cope with higher static pressures. In some cases over 1"wc. PSC motors lose airflow dramatically as static pressure rises. All manner of ECM motor seem more capable of dealing with airflow restrictions. I've been told ECM motors are more prone to failure with high static than PSC motors, but my experience doesn't agree.
So is this a myth or nah?
r/HVAC • u/SkunkWorx95 • 2d ago
1981 Cleaver Brooks fire tube. She was pretty well flooded due to a stuck open cold water fill on the condensate tank. After getting everything back to sanity, replacing and adjusting fill, and getting her up and running she was purring. I went back to check on the building a few days later and found everyone complaining it was “a little too warm” lol.
I love steam work, and my father gave me great advice while teaching me boiler work “ absorb all of what I’m teaching you so that you can be the guy in the warm boiler room when it’s -10 instead of fighting for your life on a snow covered roof.” Best advice I ever got from the old man!
r/HVAC • u/SkunkWorx95 • 2d ago
r/HVAC • u/ExternalMethod9319 • 2d ago
After a week of on call this is the aftermath so far haha How do yall find time to clean yall vans?
r/HVAC • u/RecoveryBucket • 2d ago
Little back story here. When I was doing pm on the plaza my pressure switch failed open during the heat check. Changed that out and flame would start and cut out. Corbel plate was absolutely cooked. Changed that out.
Equipment was running for 20 minutes and then shut down. It ignites and cuts out after 8 second ignition period while flame is active. Measured the flame sensor in series and got .1 micro amps. So we changed the flame sensor. Still having the same issue and getting error 2 still.
Board to ground is good, burner rack to ground is good. Flame sensor wire end to end is good. Gas pressure to manifold is good. I’m at a loss for words currently. Tech support obviously didn’t answer before I had to leave and attend another call.
Anyone seen something similar or ideas on possibilities here?
r/HVAC • u/m3x_aries • 2d ago
The stuff you see on apartment change outs are hilarious. So much mastic had to use the sawzall because my razor, knife and jobmax couldn't get through
r/HVAC • u/oHaiImJasper • 2d ago
Got a call out. RTU tripping on smoke alarm. Sensor was definitely completely clogged but I opened my compartment up and got hit with a full cloud of gas. Whoever was out here last must’ve been having a bad Friday… Pretty straightforward smoothed her out and kept it pushing. Almost wish it was a bit more catastrophic so I don’t have to get back on hot side today 🙃
r/HVAC • u/bigred621 • 3d ago
Here to replace a power venter motor but holy hell
r/HVAC • u/iBUYbrokenSUBARUS • 3d ago
r/HVAC • u/rigpiggins • 3d ago
See these all the time, I think they’re mostly caused by poor burner alignment from factory. Seems to always be hitting the high side of the flame retainer, and the crack is always on the high side as well. Another company replaced this just over a year ago. Burner alignment not corrected, very low manifold gas pressure and the inducer wheel was covered in fibreglass. I think all these contributed to the early failure. Replacements come with two year warranty from Carrier, best if you register the replacement with the unit S/N of the unit with CE.
Curious what you guys think about it though. Yes it has a crack, but is it actually compromised?
r/HVAC • u/Exciting-schmuck • 3d ago
Went to a call and this furnace really stumped me. I checked gas pressures (3.4 inches )and dc mv for flame sensor. I am a bit iffy on the flame sensor reading I cleaned and got it reading from 0.2 when I first got there to 2.1(I know it’s on the lower end of it being acceptable). But no matter what I did I could not figure out why the furnace kept sputtering and going out and on. Sometimes when it would retry to ignite after completely going out I’d get an error code after the inducer would run saying the pressure switch stuck open but then would close and correct itself shortly after. Could something be affecting the inducer or pressure switch? Could it be a sticking pressure switch causing the gv to keep on clicking on and off ? What would cause such an aggressive ignition when the burners ignite like in the video. Fairly new service tech and looking for some advice on the matter.
Edit it’s a Goodman furnace single stage.
r/HVAC • u/GreatSuit7041 • 3d ago
Well it does... But also water.
r/HVAC • u/m47playon • 3d ago
Checked around and it’s discontinued from what the suppliers said.
r/HVAC • u/milk_steak420 • 3d ago
Hello!! I got my results back for taking the ASVAB and got a 66. I feel like this score is pretty low and I’m struggling a bit to understand how I did. Am I even gnna get a call? Does anyone have any experience with getting into this union? Contemplating going to 597 and putting in an app there.
r/HVAC • u/cycling_sender • 4d ago
I work for a small shop where everything is chaos 95% of the time. I'm only a second year and came in completely green, I am also "a planner" who likes to know as much as possible before starting things (which I know only gets you so far in this trade - but I lack the experience to rely on to fly by the seat of my pants).
Installs almost never have any real plan, equipment just shows up and we're expected to figure it out.
Repair jobs often dispatched with wrong parts, missing parts, etc. I think I've worked with a journeyman <10 days in 2 years.
We do manage to keep our head above water and do good work but I feel like things would just be so much less stressful if there was a bit more organization. I don't have perspective on other companies but are there shops that actually have this figured out or is this just the way it is everywhere?
r/HVAC • u/JuicySpark • 4d ago
We all have a story about what we didn't want to do but ended up doing anyway. Like most service calls. I'm not talking about those. I'm talking about ones that make you regret entering the field.