r/HVAC • u/No_Scale9481 • Feb 23 '23
r/HVAC • u/SquallZ34 • Sep 27 '25
Field Question, trade people only What I learned today: this sub is full of resi techs that don’t know jack shit about fuck all
I bet you kids couldn’t even figure out a rooftop unit, let alone a building.
r/HVAC • u/Chief_B33f • Apr 13 '24
General Alright, which one of you geniuses put this clamp on the drain pipe?
r/HVAC • u/Mandowan • Feb 19 '24
Meme Changing out a carrier board today i they f*****g got me
Got ‘em
r/HVAC • u/briyo76isme • Feb 18 '21
I'm leaving this sub
As an HVAC service tech, i am so tired of seeing posts from the DIY guys fishing for free info from people who have poured blood, sweat, and tears into this profession. Want some help? Look it up on YouTube. Or better yet, call you local service company. Pay the $100, and let them tell you what is wrong. My feed has become inundated with posts from people who are too cheap to pay, and want a free diagnosis. Best of luck to my fellow techs. Im out.
r/HVAC • u/Forward_Hvac • May 21 '22
How does everyone get a good laugh in the field? I just bought these to be a menace to society… I’m sorry not sorry if you come across these in the field consider this the heads up to get the bit
r/HVAC • u/HaVoAC • Aug 16 '25
Employment Question You guys said earning $100k was easy, ACHR News shows conflicting information
Not a single state on their list shows supervisor level technicians making more than $100k.
r/HVAC • u/Dat_boi_negEV • Jan 28 '22
Anyone do this when on call? (video from today is unrelated)
r/HVAC • u/Chief_B33f • Jun 24 '26
Rant Rant: Core removers and special vacuum hoses are completely pointless when pulling a vacuum.
I'm sure this will get downvoted but fuck it.
I've been in the HVAC industry for 13 years and the only thing I've ever needed to pull a good vacuum is my Brute 4-port manifold and a vacuum pump with good oil. Residential systems 5 tons or less are small enough that the fancy vacuum hoses and core pullers are nothing more than a waste of money.
When installing a new system, focus on the lineset first. Braze, nitro purge, pressure test, and get the vacuum on the system before lunch. Hook up the gauges like normal without pulling the cores out, use the 3/8 hose on the pump while pulling through both the red and blue and you'll be fine. Let the pump run while you install the disconnect/whip, do the drain, sheet metal, thermostat and it'll be under 500 microns by the time you're done.
Is it as fast as pulling the cores out and hooking the pump directly to the system? No obviously not, but it doesn't matter; if you do the job in the right order.
r/HVAC • u/iBUYbrokenSUBARUS • Aug 15 '24
Rant I’m tired of seeing these companies charge $600 for a capacitor. You’d almost think they were in this to make a profit. Can you imagine going to someone’s house and expecting them to pay to keep your business running and then pay your employees too? It’s crazy and it’s gots to end sometime soon.
Whatever happened to good old philanthropy? Did it end with Paul Newman and his salad dressings?
r/HVAC • u/EJ25Junkie • Aug 25 '22
I currently make 55k a year doing HVAC. From 1996-2019 I never made more than 44k. I have four kids. My wife is a stay at home mom. In 26 years I’ve never missed a payment including my mortgage. It’s not hard if you got one ounce of morals.
r/HVAC • u/Notaprumber • Oct 22 '24
Meme/Shitpost No one cares that you quit
This sub is once again becoming "my pussy hurts and i quit" "my boss hurt my feelings" "beeeep beee beeeppp meeep waaa"
If you want to complain, go over to /butthurt, no wonder you guys didnt make it in HVAC. Go get a receptionist job and fill out the HR form when someone looks at you funny.
Someone post some blown open 15ton compressors, roofers attaching their landyard to the gas line, or stolen RTU coil pics to get us back on track
r/HVAC • u/out-trolled • Nov 30 '23
The EPA is about to fuck the industry!
Sitting through a Seminar on the future of HFCs and new standards being passed in 2024, the EPA is going to mandate the drop of production of HFC refrigerants by 80% in 2024 then 30% reduction every 2 years until 2036 where HFC production will be 0%… Snap 26 and the Aim Act are gonna fuck So many people!
r/HVAC • u/[deleted] • Aug 10 '22
Help. What do? Brand new R410a system. Already replaced TXV. Didn't take superheat or subcool.
r/HVAC • u/EJ25Junkie • Dec 05 '22
One of the best parts about doing residential work are the cars that you meet.
r/HVAC • u/Eggrollofdoom • Nov 03 '25
General How often do you run into units with no filter dryers?
Every so often I run into one.
I just ran into 2 units to do PMs on, around 20 years old, 2-ton R-22 Lennox split units. Both have no filter dryers. Both are in pretty decent condition. Looks like original compressors and fan motors. Quoted the owner on installing filter dryers on both of them.
r/HVAC • u/alfanzo1193 • Nov 17 '23
How to get fired??
They can’t replace me so they don’t fire me.
I don’t want to be here.
I won’t do anything unethical or treat them the way they do us.
Still need good relationships with my clients, they are the best part of this whole job.
Im in the process of maximizing all benefits for the year and PTO is almost empty.
I even started shitting on company time.
r/HVAC • u/iBUYbrokenSUBARUS • Mar 29 '26
General What do you all charge for hydrochloric acid cleaning a fan blades? Is this something you’ll do on every maintenance?
r/HVAC • u/[deleted] • Oct 16 '24
Meme/Shitpost When you give 110% on every job…
just to be sure
r/HVAC • u/jjmanchvegas • Apr 22 '24
Field Question 20+ years ago the AC system was installed. For 20+ years a major problem lay undiscovered or at least unaddressed by the company tasked with PMs at the location, even with countless service calls for the same reoccurring issue since installation. Can you see the problem?
Today's magic word is: Analog Gauges.
As a word of advice for newcomers to the trade: DO NOT BUY DIGITAL GAUGES.
I don't care how if you find one so fancy that they will give your wife and your girlfriend an orgasm at the same time, none of those bells and whistles can compare to the simplicity and reliability of two dials and a manifold.
No need to look up your altitude & cross reference the psia offset, no pairing an app, no Bluetooth failing to connect through a wall, no $800 price tag, no batteries dying, and no mailing your primary money making tool back to the factory to be recalibrated: an $80 analog manifold combined with a $100 thermocouple multimeter is all you will actually need for 3/4ths of the field calls you will ever get.
When I first started I got myself a cool testo setup that did everything except give me a no bullshit reading, & every single job I went on was a stressful shit show of me not being able to figure out what the fuck was wrong with every condenser I hooked up to ... Then I had one of the old head techs sit me down and showed me how reliable a set of analog gauges + a fluke with a temp setting was, and I realized that every single system balance diagnosis I had made was wrong. On top of curing all of the heartache and stress that digital set was causing, plus allowing me to get more jobs done in a day because I wasn't tripping over my dick for an hour at each call: I could have gotten 4 sets of analog gauges for the same price I paid for that testo.
This story time is brought to you by me pulling that testo set out of storage, because I needed to do some guage work after mostly sitting at a desk for several years, and getting a crash course reminder on how much of an agrivating bitch they were.
Don't be like me: I spent so much money on worthless crap when I started. All that anyone really needs for their first month is a powertool bundle & a pocket full of wrenches / hen pick out a multimeter + analog gauge set on your second month ... As long as you don't lose anything or get stuck working with a tool thief, you will be set for the rest of the year.
r/HVAC • u/bucksellsrocks • Oct 21 '25
Meme/Shitpost Im the HVAC installer that forgets he turned his furnace off last night LOL
There i was just now after a 9 hr day with no real lunch break like “is it cold in here? Fuck! I forgot to change the filter again didnt I!” Nope! Goddam switch was off because i left the window cracked but didnt notice when i turned it off at 3am because my bedroom was hot. Closed the window and left for work without turning it back on LOL