Xhïorūn ∿ Vølt-Ω - Sharp Minimax Charge Routing in Multi-Output Switched-Capacitor Converters, Exact Adaptation Limits, and Passive DC Decoupling
When several voltage rails share a switched-capacitor converter, their loads can vary independently. This work establishes exactly how much extra charge-weighted capacitor plate motion a fixed circuit can incur compared with a circuit tailored to each load mixture.
For \(m\) independently loaded outputs, the sharp worst-placement factor is \(2-2/(m+1)\). The result covers common-ground converters with two fixed switching phases, rational rail ratios, a linear periodic charge response, and a sufficiently high nominal capacitor-voltage ceiling. A constructive synthesis attains the guarantee, and explicit families of rail placements approach the bound regardless of component count. Every individual placement with at least two outputs admits a strictly better factor. The included compiler checks \(m(m+1)/2\) extreme load directions and generates a capacitor network with exact phase-charge verification.
PureOne/Xhiorun-VIII-Volt-Omega · Datasets at Hugging Face
Near-optimal passive synthesis. For a 12 V input and outputs at 1.2, 1.8, 3.3, and 5 V, the exact unrestricted linear-routing optimum is \(158/139\). A passive construction achieves a factor of approximately 1.136813176332, within 0.0108% of that lower bound, using 390 moving capacitors, 120 stationary capacitors, and 240 switching contacts.
Exact limits on adaptation. A rail-spacing criterion determines whether one stationary linear configuration can attain the load-specific optimum throughout a region of load mixtures. One four-output geometry requires exactly eight selectable configurations across all nonnegative load directions.
Passive DC decoupling. A six-contact 12 V to 4 V and 8 V circuit retains its \(8/7\) worst-load charge factor while canceling both mean cross-impedances in the specified switched-RC model. Interval arithmetic certifies a common zero between 122,110.31 and 122,110.34 Hz. At 1 A per rail, ngspice yields mean voltages of 3.890773 V and 7.890773 V, with 47.464 mV peak-to-peak ripple per rail.
The release combines a circuit-independent performance bound with constructive synthesis, exact arithmetic, and reproducible circuit predictions. The mathematical objective measures nominal charge activity. The cross-regulation result concerns steady cycle means under constant loads. Hardware efficiency, transient isolation, and commercial savings remain to be established.
The full description includes the component values, the general multi-rail decoupling construction, the exponential tree-configuration result, and suggested keywords.