Comparing Stereo and Pulse based estim devices.
Hello estimmers!
I am getting lots of questions lately, comparing “Estim Hero - Stereo” to other estim devices on the market. So, I’ve decided to post a detailed comparison, mainly from a technical standpoint.
I will compare the outputs of both types, and illustrate why stereo estim is worth chasing.
Contents
Disclaimer
General features overview
Testing method
How to read the oscilloscope
Output analysis
500Ω load
1,000Ω load
Dual-phase
Tri-phase
Conclusion
1. Disclaimer
We are manufacturing and selling a commercial estim device, so other devices are technically our competitors.
For another review of pulse-based devices you can take a look at a post series made by Medojedone “DG LAB Coyote 3.0, review by an electronics engineer”
I’ve initiated the journey to stereo estim devices because I personally was unsatisfied by existing devices.
At the time I did not know that they were pulse based, and after discovering it I’ve decided to make a high quality DIY device.
Early in the R&D I decided on making the device with PCBs instead of tons of wires, and soon after moved to a commercial approach to make this available to other people as well.
So, all of this will color my subjective impression.
Do your own research.
Without further adieu.
2. General Features Overview
| Feature | Pulse | Stereo |
|---|
| Wave generation | The box generates the signal. A processor builds pulses, then outputs them. Audio-in affects certain aspects of the pulses. | The box amplifies the source signal. File, generator, or browser makes the source signal. Amp and transformers amplify and send that wave out. |
| Waveform | Pulses. Narrow, repeated, similar pulses. The change is size and rate. | Same as the source waveform. Output depends on the input and follows it. Sine stays a sine; a wave stays that same wave. |
| Built-in patterns | Yes – a variety of patterns are preprogrammed. No external player is required. Pulse, wave, climb, etc. | No – the box is an amplifier for an external signal. Outside signal required. Patterns supplied by the outside file. |
| Feel (subjective) | Sharp and edgy. Different modes exist. | Smoother, and file-dependent. A soft file feels soft; a harsh file feels harsh. |
| Size and power | Small. Many run on a 9V battery or a small pack. A mains supply is optional on some, and raises output. | Bigger. Needs an amp and often a mains supply. Power is continuous. |
| Weight | Light. The heavy part is the case. 100g–250g | Heavier, mostly due to the output transformers. Two audio transformers plus the power supply add weight. 800g+ |
| Price | $120–$400 | $180–$750 DIY can be the cheapest. |
| Product | A pattern machine that plays alone. | A clean amplifier for estim files. The estim file contains the pattern. |
3. Testing Method
For the stereo device I will use “Estim Hero – Stereo” that we manufacture.
For the pulse device I will use a widely available estim device. It is powered by a 9V power supply.
Oscilloscope to analyze input and output of the devices.
A few 500Ω resistors as a load to simulate a human model.
A dual-phase estim file and a tri-phase estim file.
Audacity to see the waveform of the source file.
4. How to read the Oscilloscope (scope)
The scope shows voltage changes over time.
The display has the waveform, with color designating the connected channel, and a background grid for level and time measurement.
I will change the grid on each measurement to better show the relevant information, so note it on every screenshot.
On the example below:
Each horizontal step is 2[ms] (milli-second = second divided by 1,000) – see top left for the time scale.
Each vertical step is 500[mV] (milli-volt = volt divided by 1,000) – see the bottom panel for the channel scale.
Scope grid
Parameters – the scope analyzes the signal and provides some information.
The automatic frequency calculation is often incorrect for these signals due to harmonics, so you may disregard it.
Note the amplitude and RMS, as well as min and max – these show the most relevant information for our case.
Scope parameters
Scope noise – I have measured a noise with maximum amplitude of 0.06[V], and it is 2 orders of magnitude lower than a typical signal, so I will disregard it.
5. Output analysis
Source file
I will use “100Hz square vibe 50pct” for dual-phase analysis.
It is a file I often use for calibration. It has many harmonics, and has a distinct look.
For me it feels strong and sharp, but still pleasurable.
Audacity waveform
On top you can see the waveform – a sine-like signal that moves from 50% strength to 100% in square steps.
On the bottom you can see the spectrogram – the brighter lines are the stronger harmonics.
Waveform
Frequency analysis
It is more detailed compared to the spectrogram.
Note that this is on a logarithmic scale, so each vertical grid step is a big change.
You can see the dominant frequency of this file is around 800[Hz] at −2.6[dB], with more harmonics around 690Hz at −15dB, 900Hz at −16dB, 500Hz at −24dB, 300Hz and 1100Hz at −27dB, 100Hz at −28dB, and higher harmonics.
Frequency
Scope measure
Measuring the PC output on the scope, you can see the waveform matches the source file.
Source wave
Zoom in
Zoomed in even more, you can see minor deviations, but overall the waveform is very close to the source.
Enhance
Source signal parameters –
Max is 720[mV]; min is −840[mV].
(Note: PC output is not perfectly symmetric around 0.0[V].) The amplitude is around 1.52[V] and RMS is ~0.420[V].
Parameters
6. 500Ω load analysis
We need to consider a minimum load the power box outputs into.
The recommended value in the literature is 500Ω, which is supposed to simulate the human body.
(See IEC 60601-2-10; 201.12.4.104 “Limitation of output parameters”)
So I will hook a 500Ω load to the power box output and measure it.
Pulse box – 500Ω load
Raising the level to medium, you can clearly see a series of pulses.
The box is on the default “Stereo” mode and medium power.
Changing the mode changes the frequency of the pulses.
Changing the source audio volume changes the level of each.
The mode change is relatively smooth between options.
The level change has distinct level jumps of strengh.
Pulses
Zooming in on each pulse – it is similar to a negative square.
Zoomed pulse
Each pulse goes to a minimum of −25.6[V], with an RMS of 11[V].
The width of each is around 60[µs] (= 0.06[ms] = 0.00006[s]).
Pulse parameters
Raising the signal to the maximum – this is 90% of max mode. Raising the mode even more makes the pulses less stable.
Note the 20[V] and 20[µs] grids. Each pulse is around 60[µs] wide.
Maximal pulse
Here are the parameters:
Pulses are around −70[V], and RMS is 31[V]. I calculated pulse energy at 0.59[mJ].
Maximal pulse parameters
The mode changes the pulse frequency.
Note – the displayed frequency in these pictures is correct.
Minimal mode produces ~80[Hz], with pulses every ~13[ms].
Minimal frequency
Default mode produces ~140[Hz], with pulses every ~7[ms].
Default frequency
Maximum mode produces ~560[Hz], with pulses every ~2[ms].
Calculating current, I get a current of 25[mA] at a maximum frequency of 560[Hz].
Maximal frequency
Stereo box – 500Ω load
On a stereo box, ideally we want to reproduce the source signal, keep the noise down, and amplify it enough to make it estim, while adding the required safety mechanisms.
The minimal signal the box outputs is actually around the same level as the input.
Minimal stereo
Increasing the volume produces a smooth increase of the signal throughout, with no noticeable jumps.
At maximum signal there are no visible distortion.
The signal follows the source waveform up to the maximum level.
Output is the same waveform as the input source file, which is the goal.
Maximal stereo
Maximal parameters are: Amplitude of 78[V] with 21[V] RMS.
Calculating using the RMS, I get a current of 43[mA], which is below the 80[mA] figure in the table for these frequencies.
(See IEC 60601-2-10; Table 201.101 – “Pulse frequency versus applied current limits”)
Stereo parameters
Zooming in on the signal:
The signal still looks the same as the input signal.
Stereo, zoomed
7. 1,000Ω load analysis
Although the literature uses 500Ω, the actual human loads we found are often closer to 1,000–1,500Ω, due to electrodes, skin, gel, and so on.
So I also tested on 1,000Ω loads to see the difference.
Pulse box – 1,000Ω load
I’ve included the individual pulses only, because the pulse frequency did not change.
The pulse width did not change, only its level.
Minimum
Medium pulse, a clean rectangle.
Medium
Maximum
For maximal signal the parameters are: Min is −57[V]; RMS is 25[V].
Calculated current is 18[mA] at 560[Hz].
Max parameters
Stereo box – 1,000Ω load
As the tests produced the same shape as on the 500Ω loads, I will only show the maximum signal here.
Maximal stereo
The Amplitude is 117[V]; RMS is 32[V]; and current is 32[mA].
Max parameters
Signal waveform is the same.
Max stereo waveform
8. Dual-phase
Dual-phase is the most common estim method. It uses two channels and four electrodes.
The sensation stays between each of the two points, rather than moving across three the way tri-phase does.
I will connect each channel to 500Ω resistor; Right is Magenta, Left is Yellow.
A typical setup is one electrode on the cock head and the other below the balls, and the other channel connected to a bi-polar anal electrode.
Dual-phase on the pulse device
I’ve used the original cables that came with the box.
I got a series of pulses. On this particular unit left is smaller. I swapped the resistors and still got the same graph.
Pulses
On maximum settings of this unit the right is a little stronger than the left, −64[V] vs −68[V] peak. The timing of the pulses is simultaneous, and does not follow the source file.
Zoomed pulses
Left channel parameters
Right channel parameters
Dual-phase on the stereo device
On the stereo device, the waveforms match each other. The levels are the same.
Two waves align
Right channel parameters
Left channel parameters
If I move the displayed waves, you can see the match.
Here they are one on top of the other.
Alignment
9. Tri-phase
Tri-phase is a very popular estim method. It provides sensations you do not get from a single channel or dual channel.
For example it can provide a stroking sensation moving between all three electrodes in one smooth movement.
I will test over two 500Ω resistors connected in the middle to common.
This is to simulate a human model of left on the cock head, common below the balls, and right on the prostate.
Tri-phase load
Source file
The previous test used a file which is fine for dual-phase, but not for tri-phase.
For the following tests I will use a tri-phase file, “V91_Sync_Hero_1_Stim_Audio_Only” [from V91-Sync Hero Vol 1 – MHBHJ Edition].
Subjectively it has what to me feels like strokes, caresses, head play, pain sections and other feelings.
First the source from Audacity:
At around the 9-10 minute mark it looks like a series of pulsating waves.
Tri-phase source waveform
Frequency analysis
This section is centered around three frequencies: 900Hz, 1000Hz and 1100Hz at −8.2dB.
Tri-phase source frequencies
It looks similar to the last file, but the waves don’t stay matched.
Their phase changes, and one moves relative to the other.
This is what feels, subjectively, as movement or a stroking feeling.
I will attach screenshots and a video.
I’ve put the waveforms one on top of the other to show the change.
Right is magenta, left is yellow.
Sometimes the waves match, like this:
Alignment
Phase change
To see it move, here is a GIF and a video of the source file waveform.
Source GIF – click to play
https://youtu.be/asLnfzV_3N8
Tri-phase – on the pulse device
I’ve overlaid the waves the same way, only changing the scale.
One side is smaller, as in the previous tests.
When the waves modulated, the right stayed the same, while the left changed its intensity, moving up and down.
Pulses align
Zoomed out, you can see the height on the left channel moving like a wave.
Wave of pulses
Here is a pulse video.
The yellow changes with the phase of the file, followed by a zoomed-out version.
(The lag is the scope struggling with the measurement.)
Pulse GIF – click to play
Tri-phase – on the stereo device
Here you can see the amplified source signal, with the same wave movement as in the source file.
Waves match
Phase moves
Phase moves further
In the video you can see the tri-phase output of the power box, with a little music and subtitles.
Estim Hero – Stereo. Tri-phase performance.
10. Conclusion
Stereo and pulse estim power boxes are different machines.
The pulse box makes its own pulses.
Source level changes how strong those pulses are.
The pulses stay short. The mode sets the rate, and the input changes the strength.
Two channels fire at the same time.
A file with drifting phase does not show up as drifting phase on the output. On the tri-phase file, that drift showed up as the height of one channel moving over time.
It can be used on its own.
Subjective: Feel is sharp, and mostly independent of the file.
The stereo box is an amplifier with output transformers.
On the files tested, the same waveform comes out as the one put in.
Volume rise was smooth.
In tri-phase, the phase shift in the file was still there on the output.
It has no built-in patterns. The source file sets the output.
Subjective: Feel follows the file.
Pick a pulse box if you want patterns, no player, and a smaller budget.
Pick a stereo box if the estim file is the point, especially tri-phase.