r/electrical • u/Neither_Challenge_45 • 11h ago
Moving light switch
Trying to move a light switch box to front corner of wall. Any tips or tricks? First time I’ve dealt with something like this.
r/electrical • u/Neither_Challenge_45 • 11h ago
Trying to move a light switch box to front corner of wall. Any tips or tricks? First time I’ve dealt with something like this.
r/electrical • u/Retro_Enthusiast2000 • 12h ago
r/electrical • u/Retro_Enthusiast2000 • 10h ago
MEME
r/electrical • u/PaceyBishop • 16m ago
I know I should know but I don’t 😬
r/electrical • u/Strange-Company-776 • 4h ago
r/electrical • u/atleast18fruits • 5h ago
I currently have a 240v outlet with a dedicated 30A breaker in my garage that I am looking to use a short extension cable for extra tools. I was curious about wiring my own splitter using a common neutral and ground and splitting the 2 hot wires into 2 20R sockets each.
Would i be able to hook in more sockets to run more low draw appliances similar to a surge protector?
Am i gonna blow something up?
Thanks!
r/electrical • u/ExitNo9476 • 30m ago
Also there is a tiny bit of insulation under the top screw, I know. Didn’t realize that was an issue until AFTER I put it all back. Was more concerned with too much copper being exposed and instead didn’t leave enough. Will it be fine until tomorrow? Or should I cut the breaker overnight? I’m out of daylight to mess with it anymore. It doesn’t smell or get warm or make noise or anything. I actually sent a pic to an electrician who said it was fine before I put it back in and now I’m freaking out that I did it wrong lol
The screws are tight.
r/electrical • u/SwissZA • 1h ago
After our recent kitchen renovation that included a new Siemens panel, the kettle (or coffee maker, so I knew it wasn't just the kettle itself) would occasionally trip whichever of three Siemens AFCI-protected circuits I plugged them into, and I noticed this twice after hours of cooking when entertaining guests. The oven had been off for quite a while by then, so I correlated the breaker trips with heat-related expansion and contraction causing a loose connection or genuine arcing inside the walls.
I later attempted to recreate the circumstances under controlled conditions.
Running the oven for two hours failed to reproduce it, but subsequently switching on all the lights we use when entertaining brought the trips back.
tl;dr (after much debugging): Entrance lights off: no trip; entrance lights on: trip—even though the lights were on a different circuit and operated by a normal rocker switch.
I disconnected a wall-mounted LED fixture, and the kettle worked normally.
Reconnecting that wall fixture restored the repeatable trip, identifying it as the trigger.
Connecting a different LED fixture in its place still didn't cause trips.
The likely explanation is electrical noise from the LED driver of that lamp interacting with the AFCI breakers when the kettle or coffee maker on the AFCI circuit starts drawing substantial current, even though the lamp is on a different circuit breaker.
AFCIs can trip because of interference from a different circuit, so the appliance that triggers the trip (or even any other item on that circuit) may not be the source of the issue at all —and removing AFCI protection (as I've seen suggested by multiple people) is definitely not the most desirable fix.
To all those experiencing nuisance AFCI trips - do take the time to try to isolate EVERY SINGLE appliance, lamp, light, outlet, and fixture to attempt to determine the source.
r/electrical • u/Tasty-Bodybuilder152 • 1h ago
Alright , I replaced an only ceiling fan / light combo that was wired where the left switch would turn on the light in the right switch would turn on the fan. The old ceiling fan had four wires coming out of it just like I have four wires coming out of the ceiling. I have white, black, red and ground. Out of the controller box I only have 3 black white and ground. How do I wire it where if the fan remote is on I can turn the fan on without the light or vice versa from the switch. Thanks in advance for you help.
r/electrical • u/Grassy011 • 2h ago
Attempting to install BN-Link in wall switch/timer for my outdoor lights - which happens to be a 3 way switch setup. I took out both switches, and removed the black wires from both commons to identify the load/line side - everything makes sense with red & purple traveler wires, I have a common in the box, etc. However, on the load side common (pictured) there are 2 black wires on common - one back stabbed, one on the screw. Should I just add the “traveler 1” wire like the diagram? Or am I dealing with something else. If it helps, this controls 4 outdoor lights.
Line side: 1 black on common, red & purple for traveler 1 & 2
Load side: 2 black on common, red & purple for traveler 1 & 2.
r/electrical • u/CuddlefishFibers • 1d ago
Here I always assumed it was just static.
(Okay, you got me, she's just sitting on something plugged in. But still surprised/impressed lol)
r/electrical • u/Appropriate_Hope_342 • 2h ago
I bought a hardwired LED mirror (120V, 44W) but want to convert it to plug into a regular outlet.
I bought a PINFOX 3-prong, 16-gauge replacement cord. Can I use this cord, and can it connect directly to the mirror’s existing wires? Or does the grounding need to be connected separately to the metal frame?
Basically, I’m just trying to figure out if the cord I bought will work or if I need something different.
And this will not be in a bathroom.
Just trying not to electrocute myself! 🫣
r/electrical • u/ButterscotchFull7591 • 4h ago
Water is yellow I think based on the stain the white border surface…picture above is below outlet.
I haven’t seen anything wet but I constantly had my air purifier plugged in here.
Looks like it was leaking from the left outside corner of the outlet. What could it be?
r/electrical • u/poopinion • 5h ago
My camera is having issues so I'll describe. In the. ceiling box there are 2 lines running in. The black wires are all braided and capped. The white wires are open after I pulled the old light down. I did not take a picture before pulling it off which is dumb. So I'm tyring to figure out how to put the new light up when the black wires are all tied off and capped and the only place to connect my new light is on the white wires. And why are there 2 lines running into the same box?
We just moved in and its an old DIY house where the person living there did the dumbest fucking thing at every opportunity. I figure its a way to run multiple lights in the room off of 1 switch or something. But something is obviously off.
r/electrical • u/Beet_k • 4h ago
i was mudding these walls and a bit dripped onto a cord that was plugged in, i turned off the breaker and left the cord in until it dried, i wiped away what was on the outside. i know nothing about electrical so any advice is appreciated
r/electrical • u/Pronoid-420 • 10h ago
Handyish man installing a dimmer switch on a three and a four way switch
The real electrician doesn’t want to come back and finish
I put in a few dimmers, but they sometimes don’t work and I need to switch them at other outlets.
How do I test which are the travelers and how do I wire them correctly.
Tia
r/electrical • u/Impossible-Mouse-729 • 13h ago
i am getting a live neutral reverse light on my socket tester in every socket in the house and at the consumer unit 240v between neutral and earth, as you can see in the photos all the connections are in the correct terminals, i know the issue is not after the consumer unit as all the circuits have this issue so it must be before the rcbo’s, any advice or help would be appreciated
r/electrical • u/SanJoseRhinos • 1d ago
Bathroom light switch. Upper wire is hot. Both black wires are pushed in the back, but screws are loose. That’s wrong…?