Hello Iām going to try to be as thorough is possible for whomever can help me.
Console: North American Sega Saturn Model 2 (MK-80000A, 21-pin ribbon setup)
CD Drive Board: JVC EXL-P605
Replacement Laser: Aftermarket Optima-6S
Original Problem:
My original laser burned out (measured 0.028 kΩ across the pot).
Installed a new Optima-6S pickup (anti-static solder blob removed) and calibrated the potentiometer to 0.713 kΩ (713 Ω).
Before recapping the drive board, the disc did spin up, and the laser bobbed 3 times before reporting "Checking disc format" -> "Drive empty".
What Iāve Done & Diagnosed So Far:
Recapped the JVC EXL-P605 Drive Board: Replaced all 6 radial through-hole capacitors on the EXL-P605 board, verified proper polarity (- stripe orientation) on all 6, trimmed leads cleanly, and checked continuity across all traces (including a slightly lifted pad on C307, which still has solid continuity to the next trace).
Current Behavior After Recap: With the lid switch held down and a clean, factory-pressed retail disc loaded, the laser glows red and bobs up and down 3 times, then stopsāthe spindle motor never spins at all now.
Spindle Motor & Platter Checks:
Spindle motor coil resistance across the two PCB solder tabs measures 6.7 Ī© (not open).
Spindle platter height adjusted/tested between ~0.76 mm and ~1.5ā2 mm air gap.
VR301 centered at 12 o'clock and tested with slight micro-adjustments.
Cables & Switches Verified:
Laser's orange flex cable is seated straight and locked.
Wide 21-pin flat ribbon cable tested 0.000 Ī© end-to-end with no broken traces and is seated firmly at both ends.
Lid-closed microswitch is functioning (triggers the laser startup cycle).
So what do I do now? Since the disc spun before recapping the EXL-P605 board and now the laser glows red and bobs 3 times without triggering the spindle motor (6.7 Ī©), what should I check next?