r/SCADA • • Apr 11 '25

General Development of SCADA Systems

Post image
114 Upvotes

Thought you guys might be interested in my hastily built SCADA timeline. (I have definitely missed a lot of them and skipped a few ownerships)
https://github.com/hutcheb/scada-timeline


r/SCADA • • Jan 21 '26

General AVEVA System Platform is a social experiment written by aliens

57 Upvotes

I have been working extensively with AVEVA System Platform for the past few months. Everyday I work with it I lose a little sanity. Just as soon as you learn how to effectively use it, some random problem occurs that breaks some portion of the software. You have to call tech support where you talk to someone fresh out of college who has no clue how to use the software for its intended purpose (intended purpose has been lost also). After you get assigned a real AVEVA engineer, you begin to fix the issue that they even they struggle with it internally. When the problem is fixed there is no resolution on what caused it to begin with, and you are left with the impending feeling something bad is around the corner. By the time its up and running again you attempt to learn a new facet of the software, which is so brain hemorrhagingly unintuitive, you just make changes and try to find what the actual output is at runtime. If you attempt to read any documentation its located in 19 different places in 19 different ways and makes 0 sense.

I am almost convinced that the aliens that dropped us off here also wrote this software and that one day in the middle of my programming they will tear through the monitor. They will laugh at me and say we cant believe you stayed in front of the software for so long! They will give me my human patience prize and I can carry on my life using the SCADA platforms that were written by humans.

Oh and 2023 R2 SP1 P03 (latest and greatest) has a bug in it where random values will display on the OMI (SCADA) in random places. Pressure will say 840.0 randomly and you will have to change pages and change back to get the actual value. There is a complex hotfix for this that will require reboots. The license manager also has a hotfix that needs to be applied, this will prevent you from using the software. Anytime one of the MS services or processes runs magically under the wrong user, you have to run a change network account and reboot the GR. Deployment of anything has about 18000 unique failure modes. You will need to blow out wow642 in the registry alot. Getting a live usable/scalable trend to pop up takes minutes, gathering any useful data from it takes more minutes, close that trend ap out and want to run a new trend... have fun. The aaGr.exe process will need to be restarted randomly for no reason sometimes. The folder structure in programfilesx86 is insane, you will need to access files from common files, archestra, aveva, or wonderware.. Good luck determining which one you will need to access to fix who knows what. Alarming is insanely unintuitive, galaxy permissions make 0 sense. There are weird lock icons for every script time in every location and it is very difficult to determine if they serve any purpose. Add in some nested embedded symbols that use a relatively referenced tag structure and your on your way to the psych ward. Simple objects like valves end up with hundreds of extended attributes. You will have to thumb through all of those in object viewer, some very important, others useless. I have not even touched redundancy yet... Don't ever install something you don't need on a node, you will basically need to format Windows. If Windows pushes an update to the .Net framework the IDE will not open. Infact if you cant get automatic updates off (can you actually do this in Windows 11?) you are screwed. They changed all the Icons in the IDE to meaningless white hexagons. Deployed objects can become corrupt and stop historizing data. DDESuitelink objects (drivers) will need to be randomly re-deployed at times. Your start menu after install looks like your PC was injected with Corona virus. Also your task manager will look like a zombie apocalypse.


r/SCADA • • Sep 07 '26

Help In game scada help

Thumbnail
gallery
46 Upvotes

Hello, i am a computer scientist doing some personal projects, and i am seeking help, for context:
i am doing a factory in minecraft, i am using ccTweaked, immersive engineering, create, mekanism,botania, and such, to implement automation, since i lack the knowledge about automation, scada and such things, i am asking help about what to search to learn and develop my factory project, in case, the picture is about a squeezer and a fermenter, which make ethanol and plant oil, then goes to refinery to make biodiesel, the plan is to control resources production, intermediate production and biodiesel production, and then feed the biodiesel generator enough so it does not waste energy, and show graphics about it on the monitor, thanks in advance.
EDIT:
this is actually an automation project inside Minecraft using the CC:Tweaked mod (Lua programming) alongside tech mods like Immersive Engineering(beauty manufactory), Create(visual and simplier automation),botania(creation of resources and refining) and ars noveau(development of advanced resources, like making the in game accesories to build better gears,tools) and applied energistics 2 will be the logistic system delivering itens stored in drawers. I'm trying to build a SCADA-like system to monitor fluid levels, control machines via Redstone pulses, and display real-time graphics on an in-game monitor so i can manage inventorys like create vault or applied energistic(digital storing and automation of logisticis) thanks for the info :D


r/SCADA • • May 22 '25

Question Rate my HMI

Post image
36 Upvotes

This is a design of a pump station and the current screen is just process. More detailed pump and valve information will be included by pop-up but can you just recommend any suggestions for improving the main design ? Thanks.


r/SCADA • • Jul 29 '25

Ignition Ignition 8.3 beta has been released

Thumbnail linkedin.com
34 Upvotes

r/SCADA • • Oct 31 '24

General AVEVA SCADA IS A CURSE

34 Upvotes

I'm the only one Scada System Integrator that is feeling frustrated using aveva products? I used to love my job but after switching from the 2014 system platform to the 2020 I found a lot of issues like bugs and faulty redundancy that are driving me crazy. I'm really starting to hate this job. OMI is Slower AF than InTouch


r/SCADA • • May 01 '25

Help Just lost my SCADA internship

32 Upvotes

Hi,

I've never even considered writing a post on Reddit, but this situation has been jarring. I want to start by stating that I was always well aware that this was an internship and that nothing was guaranteed. I felt lucky for every moment I worked there and I devoted all my effort into it because it would've been my first engineering job coming out of graduation this upcoming May.

This company I worked for hired me during the first week of the New Year 2025. It's a very small environmental company and it was not fully dedicated to engineering, but there was a small SCADA team of 3 people. Their clients included Wastewater and Water Treatment Plants and I visited multiple client locations during my first couple weeks. I was immediately captivated and got involved as soon as possible in the work that was required to develop these SCADA panels. I scheduled Teams meetings with my mentors constantly in order to accelerate my progress and learning. I had completed a few PLC programs using Studio 5000 and I was beginning to learn about HMI programming. I had pride in every task I completed, but I was humble since I always knew there was much much more to learn with SCADA.

For 4 months, I loved my work and interacting with the clients and satisfying their needs. Whenever anyone asked me "How's your job going?" I would always say that it was an internship and that I still need to earn my place, but that I love it. About a month ago, my boss had taken me out for drinks (he had done this since I started working there, and I always appreciated it since I was merely an intern). He told me I was doing great and that the whole team had discussed that they wanted me to work more during the week. I would go from 24 hours a week to 32 hours a week. I immediately accepted and I adjusted my schedule to fit in 8 more hours and take on more work. No problems ensued. I kept up with the hours and I was constantly checking in to review my work and ask for more tasks. During the last two weeks, the team was not giving me as much feedback and tasks as they usually do. I thought it was weird, but I didn't give it too much thought since my boss was having conversations about my job at this time. He was asking me what week would be best for me to start full-time and I told him the first week of June, since this was the first week after my graduation. He said 'great' and that he was working on my official offer letter that week.

At this point, I'm still not telling anyone I have a job offer coming or that anything is official. This conversation about my offer letter was last Thursday. This past Monday, I showed up to work and proceeded with my duties. My boss scheduled a Teams meeting with me that was scheduled for 30 minutes from that moment. I joined the call first and was joined by my boss and a woman from HR. My boss let me know that my position was terminated based on my performance.

At first, I was angry. Now, I'm just confused by every single detail. Why ask me to work more hours because I was 'doing good'? Why discuss an offer letter with me multiple times over the past few months? Is it because they're a small company and there was a cut for environmental funding? Are the tariffs increasing the PLC prices and making it more difficult once we agree on a budget with our client? If my work was consistently bad over the past four months, why was there never a discussion about it? Is this the engineering intern world?

Don't get me wrong - I was not a 'natural' with this work. It was my first involvement with SCADA and I made mistakes at first, but I never made them again once I was corrected. Once I got home, I updated my resume to involve my SCADA work and I started applying for similar jobs. As the days go on, I'm progressively getting more discouraged based on how I was let go. So, I guess what I want to know - Was this whole situation odd or is this an average experience for an intern in this field? Should I stick with SCADA and keep applying? What other industries besides Wastewater and Water plants can I look for a good SCADA job?


r/SCADA • • Jan 27 '25

Question Can I call this an OT/IT SCADA Lab

Post image
32 Upvotes

New to the SCADA game, my experience is mostly OT hands on wiring and hardware. I built this lab to get better with the IT parts of our field. Any advice/tips/suggestions to make it better would be greatly appreciated.

Using modbus TCP to communicate between the micro 820 and VT SCADA application


r/SCADA • • May 28 '25

General I could not resist reposting this one

31 Upvotes

There is nothing more satisfying than when a customer like Slovenske Elektrarne (major electricity producer in Slovakia, with 2 nuclear and 31 hydroelectric power plants) publishes an article and video on its website about how its control system, built on our Ipesoft D2000 application server, has been successfully controlling electricity production in real-time... for 20 years.

And I was there from the beginning ... implementing IEC-104 protocol, installing our system on OpenVMS running on Alpha DS25 server, later on HPUX Integrity servers ...

You can see live screens of our system from the control centre (00:05, 01:19, 01:34, 02:57, 03:18) - both standard computer monitors and large wall-installed Barco displays. Historical footage of UI, rather blurred, is at 03:58.

(you'll probably need to enable auto-generated Youtube subtitles as well as automatic translation to English)


r/SCADA • • Oct 18 '24

General I feel dirty.

30 Upvotes

I never thought it would happen to me, but I was asked to integrate data from an excel spreadsheet in Onedrive into our SCADA platform.

They came prepared, with a legitimate business case and a clear narrative of how they wanted the data to flow. I was helpless, I had no choice, and once I learned Microsoft's Graph API can get a range of data from a spreadsheet in one GET call, I was truly powerless to stop it.


r/SCADA • • Mar 10 '25

General Google unintentional roast

Post image
29 Upvotes

Anyone else need to check this constantly


r/SCADA • • Apr 07 '23

General Open Source Web SCADA

29 Upvotes

The enthusiasm for coding and fascination of web technology is the power in this Open Source project: a web-based Process Visualization (SCADA/HMI/Dashboard) software.

https://github.com/frangoteam/FUXA

Features

  • Devices connectivity with Modbus RTU/TCP, Siemens S7 Protocol, OPC-UA, BACnet IP, MQTT, Ethernet/IP (Allen Bradley)

  • SCADA/HMI Web-Editor - Engineering and Design completely web-based

  • Cross-Platform Full-Stack - Backend with NodeJs and Frontend with Web technologies (HTML5, CSS, Javascript, Angular, SVG)


r/SCADA • • Aug 05 '24

Help Has anyone ever seen a program send CPU STOP to an S7?

Post image
26 Upvotes

Recently analyzed a program that was sending STOP commands to an S7-1200 directly over the network. Has anyone ever experienced this type of malware before?


r/SCADA • • Dec 16 '22

How to build a huge Ignition SCADA solution without making a mess

26 Upvotes

Heya,

Me again. I work for a Premier Ignition Integrator in Europe and we create lots of content around Ignition, from how-to tech stuff to business-level talks.

Not sure what's considered a shameless plug around here yet, but I just wanted to share with you a video our CTO and our graphic designer made, where they talk about:

- architecture

- visualisation

- reusability

- simplifying

The video: https://www.youtube.com/watch?v=iw_DY2Q_l64

Let's talk about it if you like. :)


r/SCADA • • Feb 28 '22

Scada seems to be very insecure but as long as you don't make yourself a target im sure you will be fine. Russia seems to have really messed up

Thumbnail
gallery
24 Upvotes

r/SCADA • • Aug 01 '26

Question How would you set up a secure remote engineering environment for a small PLC/SCADA team?

23 Upvotes

I run a small industrial automation and SCADA integration company. I expect several new projects in the near future and I am considering hiring approximately two engineers to support me, with most of the engineering work being performed remotely.

Before hiring anyone, I would like to build a practical and secure working environment. I am particularly interested in the experience of small system integrators and automation companies rather than large corporate IT departments.

The work may involve PLC and SCADA projects, source code, JavaScript or Python scripts, customer documentation, engineering software, simulations and potentially remote access to customer systems.

Some of the questions I am currently considering are:

- Should engineers receive only company-owned and centrally managed laptops?

- Should they work without local administrator rights?

- How do you prevent unapproved software, malware and the use of private USB drives?

- Do you install engineering software directly on the laptop or use virtual machines?

- Do you separate VMs by vendor, software version, customer or project?

- How do you manage legacy engineering software that may require administrator access, unusual network adapters or USB passthrough?

- How do you store and version PLC/SCADA projects that are not well suited to Git?

- How do you manage source code, project archives, changelogs and code reviews?

- How do you back up engineering projects and verify that the backups can actually be restored?

- How do you organize onboarding, training and technical support for junior or new engineers?

- How do you monitor progress without turning the process into micromanagement?

Another important issue is licensing.

Some of my engineering software uses physical USB license dongles. I may have two or three licenses that would be shared between engineers depending on the current workload.

I would prefer to keep the physical dongles in the office rather than sending them to employees. I am considering several approaches:

- an official network license server;

- a dedicated office workstation or VM accessed through VPN and Remote Desktop;

- a USB-over-IP device;

- USB forwarding through a remote desktop solution;

- keeping the software and the license on a central engineering server.

Has anyone implemented a reliable solution like this? How well does it work with latency, VPN interruptions, virtual machines and vendor licensing terms?

I am also preparing the organizational and legal side:

- NDA and intellectual property assignment;

- access granted only to the projects required for a particular employee;

- separation of customer data and environments;

- rules against copying projects to private computers, storage devices or cloud accounts;

- equipment handover and return procedures;

- immediate account and VPN revocation during offboarding;

- incident procedures for malware, a stolen laptop or suspected data leakage;

- rules for using AI tools with customer code and documentation;

- daily or weekly progress reporting;

- peer review or approval before releasing changes.

I do not want to build an expensive enterprise environment for a two-person team. I am looking for a reasonably priced setup that is secure, manageable by a small company and does not make normal PLC/SCADA engineering unnecessarily difficult.

My current rough idea is:

  1. Company-owned Windows laptops with encryption, endpoint protection and central management.

  2. Standard user accounts, with administrative access controlled separately.

  3. MFA for email, VPN, repositories and remote access.

  4. Engineering software separated into vendor-specific or customer-specific VMs.

  5. Central Git repositories for source code and controlled project archives for binary PLC/SCADA files.

  6. Automated local and off-site backups.

  7. Physical license dongles kept at the office and accessed only through an approved central solution.

  8. VPN access through a jump host rather than direct access to every internal system.

  9. A documented onboarding, project handover and offboarding checklist.

For those who already manage remote controls engineers:

- What does your actual architecture look like?

- Which tools do you use for device management, VPN, remote access, VMs and repositories?

- How do you handle engineering software that requires local admin rights?

- How do you manage USB license dongles?

- How do you track engineering progress and review work?

- What mistakes should a small integrator avoid?

- What would you implement differently if you were building the environment again today?

Any real-world examples, diagrams, checklists or lessons learned would be greatly appreciated.


r/SCADA • • Mar 09 '25

Question Field Technician to SCADA Engineer

23 Upvotes

I work in a project sector of renewables that requires Scada systems to be set up by an engineer that over sees the operation remotely.

A contractor sets up the system at the substation and our remote scada engineers get that hardware communicating with a server and all people who have access.

I've worked with with these people directly and have become familiar with what they need out of us as far as technicians and basic setup is concerned. Including fiber patching and schematics, and nerc security.

What additional skills or learning pieces would help me pursue this job?


r/SCADA • • Feb 16 '25

Help Scada architecture?

Post image
23 Upvotes

The entire manufacturing plant operates on a system platform where all logic and applications run centrally. Then each production line is equipped with an HMI (InTouch) to control local PLCs. In certain areas, these InTouch applications use text files stored on a shared central server created by another intouch application of the same area, which presents potential issues.

Management is considering two alternatives:

  1. Replacing the text file-based data exchange with an SQL-based approach

  2. Overhauling the entire architecture by implementing an AVEVA Edge-PLC combination for each line

I need your expertise to understand the pros and cons of both solutions also from cybersecurity point of view and which is the most ideal architecture.


r/SCADA • • Sep 23 '24

Help Update, I got the job - Somehow landed a Scara interview with no experience

22 Upvotes

My Original post a couple days ago > https://www.reddit.com/r/SCADA/s/67TO899XaK

I got the job guys. I don't know how I did it, or how it happened, but I'M IN! Zero experience! Hell I didn't even know wtf Scada is when I got called for interview lol And now I need all the advice I can get! My boss is ready to teach me everything, and I don’t want to let him down after he took a big chance on me.

I just started an SQL course yesterday, and after that, I’m thinking Python. Oh, and the salary—$91k. That’s a 62% increase from what I’m making now, and it feels huge!

So, how tough will my first month be? I’m 100% committed to putting in the work. I know people with PhDs and Masters who don’t get this kind of opportunity, and here I am with just a high school diploma. I'm incredibly lucky and blessed!

Also, what’s my earning potential in say 3 years? I plan on following the money, so what’s the best path to maximize earnings as quickly as possible? What skills should I be focusing on mastering? What tools should I learn inside and out?

Any and all advice is welcome! The role is Scada Specialist


r/SCADA • • Dec 14 '23

General Friendly reminder to NOT do any major changes next Wednesday/Thursday/Friday as Christmas is on the following Monday.

22 Upvotes

I love my site folks, they fully support my request to not make major changes late next week.


r/SCADA • • Apr 19 '20

Control Engineer Networking Discord Server

22 Upvotes

If anyone interested in joining a Control Engineering Discord Server where control engineers network and discuss anything related to PLC, SCADA, RTU, PAC to DCS. This is the link, the server has 3700 members. Looking for someone who has experienced in ABB controllers since we do not have many. Below is the link to join.

https://discord.gg/TPPGVvt

Please type the below command once you joined.

?rank control engineer


r/SCADA • • Sep 16 '26

General I'm working on another Modbus simulator; I'd appreciate some feedback.

Post image
21 Upvotes

I've been developing a Modbus simulator for quite some time now.

He has several tools, especially a sniffer Modbus RTU which shows network traffic (requests and responses).

It can also be used to find out what the master or client equipment (if it's TCP) is sending.

For anyone who can, I would greatly appreciate feedback (positive or negative) on the software.

The software's name is ScanBus-BR.

You can get it for free here:

www.scanbus.com.br

Mais Informações sobre ele aqui

https://github.com/ortegahernandes/ScanBus-BR-Simulator-Modbus.


r/SCADA • • Aug 23 '26

Question Are we finally past dedicated hardware RTUs, or do linux IPCs just move the headache somewhere else?

21 Upvotes

curious what people running actual fleets are seeing here.

the pitch for IPCs is easy to like. rugged linux box in the cabinet, containers for the protocol stacks, python or go for whatever the vendor never built, mqtt or opcua out the top. you stop waiting on an RTU vendor to add a point type and just write it yourself. that's software defined automation and on paper it works. but the old proprietary RTU has one property people undersell. it does one thing for fifteen years and nobody thinks about it in between. put a general purpose OS in the field and you inherit patching, kernels going end of life, container images picking up CVEs, and a fleet where box 300 has quietly drifted from box 1. in critical infrastructure that stops being annoying and starts being an audit finding.

how are your field teams handling OS updates across a few hundred IPCs? A/B partitions with rollback, immutable images, or is somebody still SSHing into them one at a time? and how did you sell operations on a box that changes being safer than one that never does?

related to that, what are people actually running underneath. plain debian or ubuntu keeps costs down but you own the whole lifecycle yourself. red hat gives you long support windows, image mode and bootc for atomic OS updates, and a support contract someone can point at during an audit. suse has a similar story with transactional updates and snapper rollbacks. proxmox shows up a lot where people want VMs and containers side by side without paying for a full hypervisor. all of them solve the update problem differently and i'm not convinced the industry has landed anywhere yet.

how much are you processing at the edge versus just forwarding raw telemetry to SCADa and the historian? deadbanding at the gateway saves bandwidth, but every transform you push into the field is logic sitting somewhere nobody opens during an incident. i've seen thin gateways flood a historian and i've seen edge boxes so clever the central system couldn't reconstruct what happened.

underneath all of it, i wonder how much devops actually survives contact with a substation. configs in git, CI on your protocol mappings, staged rollouts, drift detection against a known good state. normal in a datacenter, mostly foreign in the field. and most of that tooling assumes you can redeploy whenever you want, which you can't when the box is behind an outage window.

what's working and what turned out to be a mistake?


r/SCADA • • Nov 20 '25

Question Moving from Software developer into Controls, Process, Automation (SCADA) in Australia

21 Upvotes

Has anyone moved from Software developer into Controls Engineer? Thinking of making the plunge, but wondering if anyone has done this in Australia? Is the demand strong? Are these types of careers typically for 35 years and younger?
Thanks