r/AskElectricians • u/nutellamuffins • 23m ago
Before I put the cover plate on, does my dishwasher junction box look safe?
There is a plastic in the bottom left KO
r/AskElectricians • u/nutellamuffins • 23m ago
There is a plastic in the bottom left KO
r/AskElectricians • u/afn45181 • 25m ago
Decided to change out a light switch since it has been making sparking sounds…. Now I I know why.
r/AskElectricians • u/bad604drivers • 34m ago
I found these old outdoor Xmas lights without the bulbs in my garage.
Can I use them as an outdoor extension cord to connect LED Xmas lights since the Lights can’t reach my outdoor outlet ?
Or will it burn down the house and electrocute the dogs?
r/AskElectricians • u/No-Deer-5347 • 40m ago
Saw this at a Home Depot. What is this? Never seen anything like it.
Canada
r/AskElectricians • u/Adventurous_File_373 • 42m ago
So I recently bought a house that came with four hardwired Kidde smoke/CO detectors, and tonight has been an absolute nightmare.
Out of nowhere, every single smoke detector in the house starts screaming “FIRE! FIRE! FIRE!” Not the annoying low battery chirp, but the actual full-blown fire alarm.
One of my roommates had been burning a candle, so naturally we assumed that was the problem. Ended up calling 911, firefighters came out, checked the house and couldn’t find anything. They also thought it might have been the candle.
We opened all the windows to air out the house, and somehow these damn things are STILL going off.
Now here’s where it gets interesting. Earlier today, I had an electrician install eight new outlets and two new circuits in my basement. I have absolutely no idea if that’s related or just a really unfortunate coincidence.
The detectors appear to be Kidde 30CUA10-V models. I started digging around online and found a CPSC complaint about someone experiencing almost the exact same thing with these detectors. Apparently, Kidde ended up sending them replacements.
At this point, I genuinely don’t know if I’m dealing with faulty detectors, construction dust, an electrical issue or something else entirely.
Has anyone dealt with anything remotely similar? Especially electricians or people who work with fire alarm systems. Could one bad detector be setting off the entire house? Could the electrical work have something to do with it?
I’m planning on contacting Kidde and getting the electrical work checked, but I’d really appreciate hearing from people who actually know what they’re talking about.
TL;DR: Four interconnected Kidde smoke alarms keep announcing fire despite the fire department finding nothing. Had electrical work done earlier today. Trying to figure out what the hell is happening.
r/AskElectricians • u/Civ_Eng0625 • 43m ago
Can someone educate me why my AC outlet is connected through the 3rd switch from the right (the blue one). Why there are 2 distinct blue ones on my DB and I can't seem to locate the outlet(s) allocated for "SACU" from my DB. I'll attach photos for your references. Thank you
r/AskElectricians • u/The_Silver_Nuke • 46m ago
I regularly distill tap water as my local water quality can be occasionally subpar. I believe one of my power cables was exposed to moisture, melting the plastic and adhering it to the socket.
If I were to ask someone, would it be possible to get it professionally repaired? I'd hate to write off perfectly good equipment over this. The distiller itself was only $120 as well. If it's more expensive to have it repaired than that I may as well toss it.
Any input?
r/AskElectricians • u/foo-bar-28 • 1h ago
We have a few portable distros that have 6 20A MCB breakers in them. The 6 outlets are GFCI. If we use LED fixtures, especially LED string lights, the breakers will randomly trip. The GFCI does not trip, only the breaker. This also happens when we use other types of LED fixtures for stage lighting. Typical load on a circuit would be about 200w to 800w. The MCB breakers are DIN style and have a C breaker curve.
So, why are the tripping? Is a C breaker curve too sensitive for LED fixtures? Are the breakers just failing? If we use distros with a Square D QO breaker theres no problems, ever. We even have construction style distros with GFCI breakers, and they work fine as well. Its just the MCB breakers that trip.
My first thought was Inrush when the lights switched colors, but string lights are constant and other LED fixtures will trip the breakers without any change, just on a steady color.
What am I missing? I there another breaker curve we should use?
Thanks for any ideas!
r/AskElectricians • u/Downbarley810 • 1h ago
This is a mix of "what is this" and "can I do this". This is on our back porch and from what I could tell using Google might be a phone box? We don't have a landline, but my objective of trying to figure this out is if it would be possible to use it to install an outlet. I would only be using it to draw ~150 watts or so, but any advice would be appreciated even if its just "That's stupid, don't do that."
r/AskElectricians • u/Helpful-Pea4259 • 1h ago
I have a detached shed about 40 feet from my house that is already wired with lights and receptacles, but currently isn’t receiving any power.
I’ve located where the existing electrical wire comes into the shed from underground, but large tree roots have grown over it, making it nearly impossible to dig up and trace back to where it enters the crawl space. I’m also unsure whether it’s still connected to the breaker panel.
I’m considering running a new electrical line from the house. I have some shipboard electrical experience and some basic handyman experience, but I’m by no means a residential electrician.
Would it make the most sense to dig the trench myself and have an electrician handle the actual wiring and connections? Or would it be worth having someone troubleshoot the existing wiring first?
Unfortunately, I don’t have a huge budget to throw at an electrician, so I’d like to do as much of the labor myself as reasonably and safely possible, or all of it if feasible.
I’m feeling a little overwhelmed by all the different ways to approach this. What would you guys recommend, and what would be a reasonable ballpark cost?
Thanks in advance!
r/AskElectricians • u/ButterscotchFull7591 • 1h ago
I see this singular stripe coming from an outlet in my room. Behind this outlet is my closet. I tried cleaning the stain it left with water and paper but it remains…I just noticed it today and am unsure of the liquid that left it but it looks like it came from my outlet…I think it’s a yellow liquid because the bottom of my floor has a white detail and it looks yellow…does it look like a leak or why could this be?
r/AskElectricians • u/sfmcfar • 1h ago
Hired a licensed electrician to install three ceiling fan boxes over my covered patio. Patio is covered by 3/4" plywood. This is what I got. And the boxes areonly screwed into the plywood, not the deck joists.
Thoughts?
r/AskElectricians • u/Grouchy-Total-2777 • 1h ago
i’m installing a new ceiling light but a little stumbled could anyone help out ? The grey wires in the ceiling are definitely the hot wires right and i would just cap a white a black because the new light has one connection.
r/AskElectricians • u/Bl3achh_ • 1h ago
At my step-dads house and I feel really uneasy..
r/AskElectricians • u/SexyAdmixture • 2h ago
I wanted to add an outlet to my utility closet at home because we have a rechargeable Dyson vacuum. The wall mounted hanger has an inlet to plug the ac adapter into.
After poking around the only option was to put a ceiling mounted outlet in this closet. I was able to mount an old work box to an existing joist above the drywall
Our library has a free (up to a certain weight) 3d printer. So I designed this “z” bracket. To hold the ac adapter in place. The adapter is snug in the outlet so is this just overkill?
r/AskElectricians • u/DeathIsTasty • 2h ago
This refuses to go into my outlet, any reason why and if so how do I fix it?
r/AskElectricians • u/ebaylus • 2h ago
Hi, I had a flagpole installed. It has an LED for illumination. Some days it works for a bit, other days it just flickers away.
The installer, and his electrician, have been out several times. Any thoughts on what might be the root cause?
Thanks so much!
r/AskElectricians • u/routern7 • 3h ago
r/AskElectricians • u/routern7 • 3h ago
Hello, I'm in California, in an older house with a screw-in glass fuse panel. Here's what happened:
The dishwasher (Samsung DW80CG4021SR) plugs into an outlet under the sink. The plug and outlet are now blackened and scorched, there was a burning smell, and the plug is stuck in the outlet.
The garbage disposal plugs into the lower half of the same outlet and still works normally.
The glass fuse for that circuit is blown. I haven't replaced it.
Cleaners were in the house shortly before this. I don't know what they did. They may have run the dishwasher, plugged something in, or bumped the cord. I can't tell if that's related or a coincidence.
My questions:
Is it safe for me to open the fuse panel and unscrew that fuse? Is there anything I should do first? I haven't touched anything since it blew.
What's the safe next step? Should I pull the fuse, leave the stuck plug alone, and call an electrician? Or can I replace the outlet myself?
How likely is damage to the wiring behind the outlet? What should I look for (discolored or brittle insulation, melted wire ends, burn marks inside the box)?
What could have caused it? I'm wondering about a loose connection, an overloaded circuit, a bad cord, or something else, since two appliances share the outlet.
r/AskElectricians • u/Both-Bluejay-2393 • 3h ago
Please be very gentle. I have absolutely no electrical background. Just a lady that was trying to figure out an electrical issue and happened upon this. And now I have questions.
So, while try to find the source of some significant electrical usage, I purchased a thermal imaging camera. For background, my kwh had literally doubled so i was desperate to find any answers. But after some sleuthing I was able to definitively identify the HVAC as the source that everyone was trying to say wasn't. But anyways, in the investigation process I took the electrical panel off and now I have a few unrelated questions.
I took temperature readings with the thermal camera. Is this any cause for concern (image 1)? The two upper colored breakers are GFIs and the bottom colored breaker with wires is the water heater. I know that GFIs tend to run hotter. Although not pictured, when i did the readings for the water heater, it was in a similiar range as the temps pictured. I know it's not a gigantic temperature difference like some say is required for significance. But the wires lighting up at all & having a higher temperature gave me pause.
But most importantly, help me understand is this panel (and house) wired correctly. I'm no expert, so again, please be nice. Lol.
Ok, so, the GFIs that I see are labeled and wired for the 1. master bedroom, smoke detectors, and 2. secondary bedrooms (image 2). I tested. There are no physical GFCI outlets in the master bedroom or kitchen. There are no other breakers like this in this panel. However, (image 3) on the panel, on the right side you see several breakers labeled ___ gfi. But they don't look like GFI breakers and dont hv a test button. Is it possible for a GFI to NOT be equipped with a test button? Bc they appear to be standard 20 Amp breakers to me. This just doesn't seem right to me. And if I'm right, what does this mean? Should I be concerned? Is this dangerous?
I live in Texas. The house is 20 years old & was built in 2006.
Thanks in advance for any input!
r/AskElectricians • u/redyellowpotato • 4h ago
I’m replacing an existing duplex receptacle with a Leviton CC1P3 USB-C receptacle and have a few questions about the existing wiring before proceeding.
The existing receptacle is installed in a metal electrical box. There are:
● Two yellow wires connected to the same brass terminal.
● One red wire connected to the other brass terminal.
● White neutral wires.
● No visible bare copper or green grounding wire anywhere in the box.
The existing receptacle appears to have an intact connecting tab between the hot terminals, so I don’t believe it’s a split-wired receptacle.
I plugged in my Klein RT250 receptacle tester, and it indicates CORRECT, despite there being no visible ground wire.
A few questions:
Could the metal box be grounded through metal conduit or another wiring method, even without a visible grounding conductor?
Is the RT250’s CORRECT reading enough to suggest the box is grounded, or could this be a bootleg neutral-to-ground connection?
How would you properly verify whether the metal box is grounded?
If the box is properly grounded, can I connect a grounding pigtail from the box to the CC1P3?
Are there any concerns with the two yellow wires sharing the same terminal on the existing receptacle?
I’m trying to understand the existing installation and make sure the replacement is safe and compliant rather than just swapping the receptacle and hoping for the best.
Photos of the existing wiring attached. Appreciate any insight!
r/AskElectricians • u/NathanJax • 4h ago
First off, thank you for looking/helping. I really appreciate any help you can give. So I had a 240v installed in my garage. My question is... does this setup look ok? Should there be some type of cable clamp going in to the panel and in to the junction box? Would this pass inspection (Florida)?
Edit: Thanks to you all! The box was originally a 50 amp ev plug and then changed to go to the charger. Can anyone also link the products I would need to get to fix this....
r/AskElectricians • u/Existing_House_5381 • 4h ago
I have an hepd80 surge suppressor that is supposed to mount through a 3/8" KO. I dont really want to cut through the drywall to install this and replace it in the future. I have enough space withing the gutter of the panel to install it. Is there any reason that it cannot go inside the panelboard? Any tips to mount it?
r/AskElectricians • u/Ravy1201 • 4h ago
Found this box on the inside wall of my garage and it seems to be connected to my home breaker box/panel that is external to the same wall. Is this some type of control box to control when certain external lights of the home turns on?