r/FireProtection • u/[deleted] • Jan 27 '14
r/FireProtection • u/Nessus • Aug 14 '14
When the architects give you 25% less space than you requested, and you've spent 6 hours trying to make it fit, you end up with file names such as attackofthetestheader.cad (X-post /r/engineering)
r/FireProtection • u/Ivo_mma • Mar 30 '17
NICET LEVEL 1
Does anyone have books or software i can download to study... I been short on cash and was going to sign up but can't afford the books at the moment. but i wan't to study to get my nicet level one
r/FireProtection • u/[deleted] • May 14 '14
What was your worst fire protection project?
I have many to list, but my least favorite as a fitter was a magnesium casting plant.
It was a HUGE facility and we had to retrofit a system in a pit that ran underneath all of their giant machines. It contained a conveyer that caught all of the scrap magnesium. The pit had this awful smell, deafening noise, slime on the floor, and giant pieces of scrap crashing down right next to us.
We had to run a 4" main the whole length (about 700ft) and install uprights all over the place. The obstructions were mind boggling.
Only took 2 weeks, but it was hell!
r/FireProtection • u/sfall • Feb 25 '15
Mid week code
I am would like to see this subreddit grow. There are places like eng-tips but that old style forums turns me off. While I don't what it would or could become I was thinking we could get some weekly discussions going.
My idea for this post we weekly post about a code or reference section we have come across or dealt with.
This one comes from the IBC 2012 (first introduced in 2009) 403.3.1. It states that high rise buildings >420 feet shall be supplied by two risers, each riser shall supply alternate floors. (Paraphrased)
I read some more about it and found that it was introduced after the 9/11 WTC NIST Report.
r/FireProtection • u/sfall • Jan 13 '15
Chicago firefighter sues Elkhart Brass over high-rise firefighting device invention
r/FireProtection • u/Ansul_Man • Aug 29 '14
Oops - Sorry about your helicopters
Nothing like accidentally deploying the helicopter hangar foam system. Here's the story.
r/FireProtection • u/thammies • Oct 11 '16
is sprinkler design a good career starting point?
Hello all,
I'm currently a senior studying mechanical engineering. However, I have an interest in fire protection. I'm considering taking an online masters degree in fire protection engineering and working after graduation at the same time. I was wondering if working as a sprinkler designer would be a good starting point for a career? Would I be able to transition from sprinkler design to consulting, insurance, or DOE work? What career paths would be available?
Thanks
r/FireProtection • u/HoLLyWo0d96 • Jun 27 '16
Hydraulic calcs
I'm running hydraulic calcs on a job using hydra Calc and I can't get the system to work. My dad uses an older dos base Calc program and he get the system to flow with safety. What could be causing the discrepancy between the two programs?
r/FireProtection • u/Ansul_Man • Feb 13 '16
Two tech's injured when fire extinguisher explodes
This happened yesterday 2/12/16. It appears that one tech has lost both legs, and the other tech has lost one leg. http://www.firefighterclosecalls.com/news/fullstory/newsid/226396
I'm curious what they where recharging. One news article said Ansul restaurant system, but that doesn't require pressure, as it has a separate nitrogen/CO2 cartridge.
Is there anyone from the area with more information?
r/FireProtection • u/brightvalley • Jan 06 '16
When Good Fire Sprinklers Go Bad: 5 Critical Steps to Safety
r/FireProtection • u/sfall • Apr 02 '15
Ok we are moving to a new subreddit /r/firePE
r/FireProtection • u/sfall • Mar 05 '15
Weekly code and standard discussion
I am hoping to build this into a weekly discussions about thing we find in the code.
Be it just interesting or you have a question.
r/FireProtection • u/sfall • Feb 17 '15
Sprinkler relocate hydraulic calculations
I have been seeing more ahjs requiring calculations on fire sprinkler relocate projects. What criteria does the fire Marshall use and what code/standard do they reference?
r/FireProtection • u/cr0n1c • Jul 05 '12
As Furniture Burns Quicker, Firefighters Reconsider Tactics
r/FireProtection • u/Veritas33 • Jul 03 '12
Welcome to the Fire Protection subreddit!
Good News Everyone!
I'm proud to introduce the Fire Protection subreddit! I'm really looking forward to where this could go, and I'm very open to any input you may have to make this a great community.
Who all is this for? Anyone involved with: Fire Sprinkler Fire Alarm Fire Extinguishers Fire Suppression Contractors, AHJ, Manufacturors, etc.
I would love a great balance between new products, techniques, code, and discussion. Feel free to start submitting and inviting your friends.
Thanks! Veritas33
r/FireProtection • u/donaldkerstetter • May 08 '23
FCF National
We are passionate about our industry and what we do, we care about our customers
and deliver what is needed for their specific business, as well as meeting State
compliancies.
Our leading edge systems, equipment and training are second to none.It is our pledge to conduct business ethically, honestly, with the customer's best interests in mind, in accordance with best practices and abide by applicable laws in all states and territories in which we
operate.
r/FireProtection • u/unforgettableid • Apr 21 '17
Buying fire extinguishers for home use: disposable vs. refillable
I live in a three-story split-level house. The highest floor is the second floor. The lowest floor is the "true basement".
We have a disposable 2.5-lb 5-B,C dry-chemical kitchen fire extinguisher (First Alert KFE5-A). It's about 15 years old. It's never been used. The built-in pressure-checking widget indicates that it's still fully pressurized. It's on the main floor, outside the kitchen.
I think I may want to buy some more fire extinguishers for the house. Preferably not too many more; but they can weigh as much as is necessary.
My questions
A) What do you recommend?
For environmental reasons, I'd rather buy rechargeable extinguishers which are useful for decades. Not cheap ones which must be discarded after a decade or so of non-use.
B) In America, is it cost-effective to buy and service good fire extinguishers, or is it much cheaper to keep on buying and discarding cheap disposable ones?
Edit
C) Should I buy refillable extinguishers with a metal valve, or disposable extinguishers with a plastic valve?
D) If you answered "disposable", how long should I keep them for?
r/FireProtection • u/heymoon999 • Apr 16 '17
How do I safely use a fan heater to heat a DIY Kotatsu (Japanese heated table)?
Heater looks like this but luckily I think the input vent is on the back, so it will be easier to leave it uncovered.
Here is a plan of the general idea.
If the only vent for input is at the back, is the setup safe as long as I leave the input and output vents unobstructed and not leave it on constantly? Where do the dangers of using a fan heater for this come from and how can I minimize each area of potential risk?
Many thanks :)
r/FireProtection • u/thuglifecarlo • Mar 29 '17
Broken Dry pipe sprinkler head and deluge system activation?
I have a dry system that had a broken sprinkler head. The foam system that augmented the dry pipe system also activated. I'm wondering what came first: the broken sprinkler head or the foam system activation? The dry system may have had residual water in its pipes, but shouldn't have been filled with water to the point that the pipes would freeze and cause the sprinkler head to burst open. This is what I'm looking at:
Pumps can provide about 120 PSI.
Sprinkler heads are hydrostatically tested at 500 PSI (So I'm assuming that a dead heading pump can't be the reason for this sprinkler head bursting)
Sprinkler head has a freezing point of -65 degrees, which can't be met in a location where winters are 20 degrees Fahrenheit normally.
Sprinkler heads have cages and are located in a locked room so animals can't break them open.
The room became 10 degrees colder than the outside due to the facility manager turning on their exhaust fans.
The deluge system uses a Viking J-1 flow control valve, but does not have a deluge valve above this valve.
The Desiccant filter has expired.
I'm really wondering why this sprinkler head is broken? What caused this system to trip? Can a sudden decrease in temperature activate a dry system?
r/FireProtection • u/[deleted] • Mar 21 '17
Reconditioned fire sprinkler?
I was under the impression that a fire sprinkler can not be taken out of service and then placed back into service unless you take the fitting or drop with it. This is something I read on NFPA journal technical committee website. While taking a test, I came across a reference to a reconditioned fire sprinkler being allowed to be placed back in service. This led me to believe it was talking about just the sprinkler.
Is this accurate? What is a reconditioned sprinkler?
Thank you